      • Working Temperature
      • -10C to +55C
      • Coil Power
      • 3 VA
      • Contact Resistance
      • <50 m at 1A 6V DC
      • Protect Feature
      • Detects Phase Failure, Sequence, and Unbalance
      • Contact Material
      • Silver Alloy
      • Contact Form
      • 1 Change Over (1C/O)
      • Dielectiric Strength
      • 2 kV for 1 Min
      • Coil Voltage
      • 415V AC (Built-in for Three Phase)
      • Ambient Temperature
      • -10C to +55C
      • Power Consumption
      • Approx. 3 VA
      • Mechanical Life
      • 10 Million Operations min.
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >100 M at 500V DC
      • Theory
      • Electromagnetic Relay
      • Usage
      • Phase Failure/Sequence Protection
      • Contact Load
      • 5A at 250V AC (Resistive)
      • Operate Time
      • 1.5 sec (Max)
      • Terminal Type
      • Screw Terminals
      • Rated Voltage
      • 415V AC
      • Supply Terminal
      • L1, L2, L3 (Three Phase)
      • Size
      • Standard
      • Color
      • Off White / Grey
      • Dimension (L*W*H)
      • 22.5 x 77.5 x 110 mm
      • Weight
      • Approx. 140 g
      • Mounting Type
      • DIN Rail Mountable
      • Phase Unbalance Trip Level
      • 30% ±5%
      • Frequency Range
      • 50/60 Hz
      • Reset Mode
      • Automatic
      • Phase Sequence Indication
      • Provided
      • Response Time
      • <200 ms (Releasing)
      • Output Indication
      • LED Status Indicator
      • Enclosure Material
      • Flame Retardant ABS Plastic
       
       

      About Minilec Phase Failure Relays VST D1

      Minilec Phase Failure Relays

      OVERVIEW :- 

        Phase Failure, Phase Sequence,
        Under voltage, Auto Reset,
        Adjustable trip delay,
        1 CO output relay
       

      Selectable range of supply voltage

      TECHNICAL SPECIFICATION :-

       

      Supply Voltage    
        System : 240 / 415 / 575 V AC 3 Phase (±15% selectable)
        Auxillary : Built In

      Output Contacts : 1 CO

      Trip Setting(Volts)    
        Phase Sequence : Yes 
        Phase Unbalance : NA

        Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      80% of V set
      80% of V set
      80% of V set
        Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      NA
      NA
      NA

      Trip Time Delay
        On Phase Failure : 0.2 - 10 secs. (variable)
        On UV/OV : 0.2 - 10 secs. (same for UV & SP)

      Resetting Mode : Auto

      Weight : 300 gms.

      Dimensions (mm)
        Overall (L x W x D) : 76 x 30.5 x 117.5
        Mounting (L x W) : 68 centre to centre / 35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      * CE marked products available on request.

      APPLICATION

      Suitable for Various equipment's using 3Phase System supply voltages like 230 V, 415 V, 440 V, 500 V, and 575 V AC.
      Examples-

      Mining equipment & Machines.

      3 Ph. Motors for Mining equipment.

      Compressor Motors for drilling equipment.

      VST D1VST D1



      Efficient Three-Phase Protection

      Protect your electrical equipment from operational disturbances with the VST D1 relay. It diagnoses phase failure, incorrect phase sequence, and unbalanced voltage rapidly, ensuring continuity and safety. This makes it an indispensable component for industrial and commercial installations reliant on stable power supplies.


      Automatic Reset and Quick Response

      The relay offers a swift response, releasing in under 200 ms and operating within 1.5 seconds, automatically resetting after the fault is cleared. This minimizes downtime and ensures constant monitoring without manual intervention, maintaining operational efficiency.


      Durable Construction and Easy Installation

      Built with flame-retardant ABS plastic, the VST D1 withstands harsh environments and high mechanical stress. DIN rail mounting and screw terminals simplify installation, making it suitable for both new panels and retrofit projects. The compact design ensures hassle-free integration into standard electrical enclosures.

      FAQs of Minilec Phase Failure Relays VST D1:


      Q: How does the Minilec Phase Failure Relay VST D1 indicate a phase fault?

      A: The relay uses a LED status indicator to provide clear visual feedback when a phase failure, sequence error, or voltage unbalance is detected.

      Q: What is the process for installing the VST D1 relay?

      A: The relay is DIN rail mountable and features screw terminals for secure electrical connections. Simply mount it to the DIN rail and connect supply terminals L1, L2, and L3 as per standard wiring practices.

      Q: When does the VST D1 trip for phase unbalance?

      A: The relay trips when it detects a phase unbalance of 30% 5%, helping protect devices from issues caused by uneven voltage distribution.

      Q: Where can the Minilec VST D1 be used?

      A: It is suitable for phase failure and sequence protection in industrial, commercial, and critical infrastructure environments using three-phase electrical networks.

      Q: What benefits does automatic reset provide in this relay?

      A: The automatic reset feature ensures that the relay resumes normal operation once the fault has been cleared, eliminating the need for manual intervention and reducing downtime.

      Q: How does the relays enclosure enhance safety?

      A: The enclosure is made of flame-retardant ABS plastic, which minimizes fire risks and provides robust physical protection for internal components.

      Q: What advantage does swift response time offer?

      A: A quick response time (<200 ms for releasing) helps prevent equipment damage by immediately isolating faulty phases, supporting safe and reliable system operation.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays VPG D1

      Minilec Phase Failure Relays VPG D1

      Contact Resistance : Below 50 m

      Protect Feature : Other, Phase failure, phase sequence, under/over voltage protection

      Contact Material : Silver alloy

      Insulation Resistance : More than 100 M at 500V DC

      Working Temperature : 10C to +55C

      Dimension (L*W*H) : 85mm x 35mm x 65mm

      Minilec Phase Failure Relays S2 VMR3

      Minilec Phase Failure Relays S2 VMR3

      Contact Resistance : < 50 m (initial)

      Protect Feature : Other, Phase failure, Phase sequence, Phase unbalance, Asymmetry, Under/Over voltage

      Contact Material : Silver Alloy

      Insulation Resistance : > 100 M at 500V DC

      Working Temperature : 10C to +55C

      Dimension (L*W*H) : 78 mm x 22.5 mm x 70 mm

      Minilec Phase Failure Relays S1 VMR7

      Minilec Phase Failure Relays S1 VMR7

      Contact Resistance : < 50 m

      Protect Feature : Other, Phase Failure, Phase Sequence, Under/Over Voltage Protection

      Contact Material : Silver Alloy

      Insulation Resistance : >= 100 M at 500V DC

      Working Temperature : 10C to +55C

      Dimension (L*W*H) : 78mm x 22.5mm x 104mm

      Minilec Phase Failure Relays ALV D2

      Minilec Phase Failure Relays ALV D2

      Contact Resistance : 100 m (initial)

      Protect Feature : Other, Phase Failure, Sequence, and Unbalance Protection

      Contact Material : Silver Alloy

      Insulation Resistance : >100 M at 500 VDC

      Working Temperature : 10C to +50C

      Dimension (L*W*H) : 77 x 22.5 x 110 mm