Monitoring Relays VCT D2
Monitoring Relays VCT D2 Specification
- Dielectiric Strength
- 2kV for 1 min
- Contact Material
- Silver Alloy
- Mechanical Life
- 10 Million Operations
- Protect Feature
- Phase Sequence, Phase Failure, Under/Over Voltage
- Power Consumption
- Less than 3VA
- Contact Form
- SPDT
- Contact Resistance
- Less than 100 m
- Product Type
- Monitoring Relay
- Insulation Resistance
- > 100 M at 500V DC
- Theory
- Electromagnetic Relay
- Usage
- Industrial Automation, Electrical Panels
- Contact Load
- 250VAC, 5A Resistive
- Operate Time
- Less than 100ms
- Rated Voltage
- 415V AC
- Size
- Compact
- Color
- Grey
- Dimension (L*W*H)
- 22.5 mm x 75 mm x 95 mm
- Weight
- 120g
About Monitoring Relays VCT D2
Established in the 1990, we are counted among the illustrious suppliers, traders and distributors of a wide range of Monitoring Relays VCT D2. Extensively demanded in varied industrial and commercial sectors, these relays are known for their features like greater longevity and accurate performance. Procured from reliable vendors of the industry, these relays are offered in different specifications to suit the demands of clients. Moreover, these Monitoring Relays VCT D2 are checked on various parameters to ensure flawlessness.
Attributes:
-
Light weight and easy to install
-
Corrosion resistant
-
Auto/manual reset
-
2 CO output relay
-
3-Phase 3-Wire Under & Over voltage,
-
Auto mains failure panels
-
Generator set panels
-
Battery charger panels
-
Inverter panels
-
DC drive control panels.
-
UPS
Advanced Industrial Protection
The VCT D2 Monitoring Relay is designed to safeguard sensitive equipment in industrial automation systems. Featuring advanced protection mechanisms, such as phase sequence monitoring and voltage fluctuation detection, it helps reduce equipment downtime and ensures consistent workflow efficiency.
Reliable and Compact Design
Engineered for space-conscious installations, this monitoring relay boasts compact dimensions and dependable construction. Its high dielectric strength and robust insulation resistance enhance operational safety, making it ideal for integration into modern electrical panels.
Unmatched Durability and Efficiency
With a mechanical life of 10 million operations and minimal power consumption, the VCT D2 offers longevity alongside operational cost savings. Silver alloy contacts ensure reliable switching performance, while the relays responsive operation time supports fast data and system protection.
FAQs of Monitoring Relays VCT D2:
Q: How does the VCT D2 Monitoring Relay enhance safety in industrial automation?
A: The relay provides essential protections such as phase sequence monitoring, phase failure detection, and under/over voltage response, reducing the risk of electrical faults and damage to connected equipment.Q: What process should I follow to install and integrate the VCT D2 in an electrical panel?
A: To install the VCT D2, securely mount it within the panel using its compact footprint, connect the control and load circuits to the SPDT silver alloy contacts, and ensure all wiring respects the rated voltage and contact load guidelines for optimal performance.Q: When should I use the VCT D2 Monitoring Relay?
A: Use this relay whenever you need to protect three-phase equipment from voltage fluctuations, phase sequence errors, or phase losscommon requirements in industrial automation and electrical panel applications.Q: What benefits does the fast operate time of under 100ms offer?
A: A response time faster than 100ms ensures quick isolation of faults, minimizing potential damage and enhancing the safety and longevity of protected equipment.Q: Where can the VCT D2 be sourced in India?
A: The VCT D2 is available through industrial automation distributors, stockists, suppliers, and traders across India, making it accessible for various project requirements.Q: What makes the VCT D2 suitable for compact installations?
A: With dimensions of 22.5 x 75 x 95 mm and lightweight construction, the relay can be seamlessly integrated into systems where space is at a premium without sacrificing performance.Q: How does high insulation resistance benefit relay operation?
A: An insulation resistance exceeding 100 M at 500V DC ensures minimal leakage currents, improving system reliability and protecting both the relay and the load from insulation failures.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Minilec Voltage Monitoring Relays Category
Minilec Phase Failure Relays D2 VMR1
Coil Power : Internal, Not Applicable
Contact Form : 1 Changeover (SPDT)
Power Consumption : <2 VA
Rated Voltage : 415V AC, 3 Phase
Dimension (L*W*H) : 90mm x 22.5mm x 70.5mm
Contact Load : Other, 5A @ 230VAC
Monitoring Relays S2 CMR3
Coil Power : Approx. 1.2VA
Contact Form : 1 CO (SPDT)
Power Consumption : <2VA
Rated Voltage : 230V AC
Dimension (L*W*H) : 90 x 22.5 x 75 mm
Contact Load : Other, 250V AC, 5A (Resistive)
Monitoring Relays D1 VCT1
Coil Power : 2.2 VA
Contact Form : SPDT
Power Consumption : Less than 3 VA
Rated Voltage : 230V AC / 415V AC
Dimension (L*W*H) : 85 x 22.5 x 75 mm
Contact Load : Other, 5A at 250V AC
Monitoring Relays OFS D1
Coil Power : 1.2VA
Contact Form : 1 Changeover (SPDT)
Power Consumption : <2VA
Rated Voltage : 230V AC
Dimension (L*W*H) : 22.5 x 78 x 100 mm
Contact Load : Other, 5A 250V AC
![]() |