|
Minilec Motor and Pump Protection Relays D2 MPR1
Minilec Motor and Pump Protection Relays D2 MPR1 Specification
- Contact Form
- 1 Change Over (SPDT)
- Contact Material
- Silver Alloy
- Power Consumption
- < 3 VA
- Working Temperature
- -10C to +55C
- Coil Voltage
- 230V AC
- Ambient Temperature
- -10C to +55C
- Dielectiric Strength
- 2 kV AC for 1 min
- Mechanical Life
- >10 Million Operations
- Contact Resistance
- < 50 m
- Protect Feature
- Phase Failure, Phase Sequence, Phase Unbalance, Under/Over Voltage
- Coil Power
- < 3 VA
- Product Type
- Motor & Pump Protection Relay
- Insulation Resistance
- >=100 M at 500V DC
- Theory
- Electromagnetic Relay
- Usage
- Motor and Pump Protection
- Contact Load
- 5A at 230V AC
- Operate Time
- 1 sec (Typical)
- Terminal Type
- Screw Type
- Rated Voltage
- 230V AC
- Supply Terminal
- Top & Bottom
- Size
- Compact
- Color
- White & Blue
- Dimension (L*W*H)
- 77 x 22.5 x 110 mm
- Weight
- Approx. 180g
- Response Time (Trip)
- Within 140 ms
- Trip Class
- Class 10
- Frequency
- 50 Hz
- Indication
- LED indication for Relay Status and Faults
- Control Supply Voltage Range
- 270V-470V AC, 50Hz (Separate supply not required)
- Humidity
- Up to 95% RH (non-condensing)
- Reset Type
- Manual/Auto
- Mounting Type
- DIN Rail Mounting (35mm)
- Enclosure Material
- High Grade Flame Retardant ABS Plastic
- Standards Compliance
- IS/IEC 60947-5-1, CE Marked
About Minilec Motor and Pump Protection Relays D2 MPR1
Minilec Motor and Pump Protection Relays
OVERVIEW :-
| | Phase Failure |
| | Unbalance |
| | Phase sequence and overloading |
| | Under Current |
| | Auto/Manual Reset |
| | Adjustable current trip settings |
| Test Facility | |
| UC bypass facility | |
| Selectable overload characteristics | |
| | 2CO output relay |
TECHNICAL SPECIFICATION:-
| Supply Voltage | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
| Trip Time Delay | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
| | ||||||||||||||||||||||||||||||||||||||||
| Dimensions (mm) | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
| Note: | ||||
| ||||
|
CONNECTION DIAGRAM:-
| Timing/ Relay logic Diagram | Electrical Connection Diagram |
![]() | ![]() |
Relay contact position shown in 'Power off' condition | |
APPLICATION :-
Suitable for Panels in Following Applications:
| Air -Conditioning & Refrigeration Machines | |
| Screw Compressors | |
| Lift , Elevators, Hoist & Cranes | |
| Crusher Motors , Mining M/c | |
| End Users |
Advanced Motor and Pump Protection
Minilecs D2 MPR1 relay offers robust defence against phase failure, sequence issues, unbalance, and under/over voltage problems. Its class 10 trip characteristic and high-sensitivity design ensure your motors and pumps remain shielded from electrical disturbances, enhancing operational safety and reducing downtime.
Intuitive Operation with LED Indicators
This model simplifies monitoring by featuring bright LED indicators for relay status and trip faults. The straightforward manual/auto reset and visible status feedback empower maintenance teams to respond quickly, thereby streamlining maintenance processes and system diagnostics.
Built for Reliability and Safety
Engineered with a high-grade flame-retardant ABS body, the D2 MPR1 meets both IS/IEC 60947-5-1 standards and CE requirements. Its compact size fits easily into control panels, while a strong insulation resistance and dielectric strength ensure dependable long-term operation even in humid and demanding environments.
FAQs of Minilec Motor and Pump Protection Relays D2 MPR1:
Q: How does the Minilec D2 MPR1 relay protect motors and pumps?
A: The D2 MPR1 relay continuously monitors electrical supply and detects phase failure, incorrect phase sequence, phase unbalance, and under/over voltage conditions. When a fault occurs, it disconnects the load within 140 ms, safeguarding the motor or pump against potential damage.Q: What is the process for resetting the relay after a fault trip?
A: The relay supports both manual and automatic reset options. After clearing the fault, users can either reset it manually using the provided button or allow the device to reset automatically, making it adaptable for various operational preferences.Q: Where can the D2 MPR1 be installed, and what is the recommended mounting method?
A: This relay is designed for easy integration into electrical panels using a standard 35mm DIN rail mount. Its compact size and top-and-bottom screw-type terminals ensure secure and straightforward installation in new or existing systems.Q: What are the typical usage scenarios for this relay?
A: Primarily used for motor and pump protection, the D2 MPR1 is ideal for industrial, commercial, and agricultural applications where electrical reliability and machinery safety are paramount. It is particularly valuable in areas with fluctuating voltages or unstable power supply.Q: When should the relay be used instead of basic overload protection?
A: Choose the Minilec D2 MPR1 when protection against not just overload, but also phase failures, incorrect phase sequence, voltage unbalance, and voltage extremes is required. It offers a more comprehensive protection suite compared to conventional overload relays.Q: What are the key benefits of the LED indication feature?
A: The LED indicators provide real-time feedback on relay status and faults, simplifying troubleshooting and system monitoring. This helps maintenance personnel quickly identify issues, reducing downtime and maintenance costs.Q: Is the relay suitable for humid or harsh environments?
A: Yes, the D2 MPR1 is designed to operate reliably in environments with up to 95% relative humidity (non-condensing) and temperatures ranging from -10C to +55C, offering robust performance in demanding conditions.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Minilec Motor Protection Relays Category
Minilec Motor and Pump Protection Relays S2 CMR1
Weight : Approx. 200 g
Contact Material : Silver Alloy
Power Consumption : <3VA
Usage : Motor and pump protection in industrial panels
Rated Voltage : 230V AC, 415V AC (Selectable)
Contact Form : 1 C/O (SPDT)
Minilec Motor and Pump Protection Relays
Weight : Approx. 180220 g
Contact Material : Ag Alloy
Power Consumption : < 2.5 VA
Usage : Motor & Pump Protection
Rated Voltage : 220240V AC/110415V AC, 50/60Hz
Contact Form : SPDT
Pump Protection Relay MBMPR
Weight : Approx. 200g
Contact Material : Silver Alloy
Power Consumption : <3VA
Usage : Pump Protection
Rated Voltage : 230V AC
Contact Form : SPDT
![]() |
JAIN ELECTRICALS & ENGINEERS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





/ 35 mm Rail Mounting








