Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays D2 VMR2

      Minilec Phase Failure Relays D2 VMR2
      Minilec Phase Failure Relays D2 VMR2

      Minilec Phase Failure Relays D2 VMR2 Specification

      • Dielectiric Strength
      • 2000V AC for 1 minute
      • Coil Power
      • Approx 3VA
      • Mechanical Life
      • >1 million operations
      • Contact Material
      • Silver Alloy
      • Power Consumption
      • 3VA
      • Coil Voltage
      • 415V AC
      • Working Temperature
      • -10C to +55C
      • Ambient Temperature
      • -10C to +55C
      • Protect Feature
      • Phase failure, phase reversal, phase unbalance
      • Contact Form
      • SPDT
      • Contact Resistance
      • <50m
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >100M at 500V DC
      • Theory
      • Electromechanical/Static
      • Usage
      • Protection against phase failure and unbalance
      • Contact Load
      • 5A at 230V AC
      • Operate Time
      • 200ms
      • Terminal Type
      • Screw type
      • Rated Voltage
      • 415V AC (3 Phase)
      • Supply Terminal
      • L1-L2-L3
      • Size
      • Compact
      • Color
      • Grey/White
      • Dimension (L*W*H)
      • 90mm x 22.5mm x 73mm
      • Weight
      • 120g
      • Mounting Type
      • DIN Rail
      • Phase Reversal Protection
      • Yes
      • Applications
      • Control panels, industrial machinery, pumps, motors
      • Enclosure Material
      • Fire retardant ABS
      • Phase Unbalance Setting
      • Available, typically 30%
      • Frequency
      • 50Hz/60Hz compatible
      • Reset Type
      • Automatic
      • LED Indication
      • Supply ON and Relay ON
      • Relay Output
      • 1 Changeover contact
       
       

      About Minilec Phase Failure Relays D2 VMR2

      Minilec Phase Failure Relays

      OVERVIEW :-

        Suitable for 3 Ph-4W system,
        Microcontroller design,
        Absolute values of UV/OV settings,
        Phase Failure, Unbalance,
        Phase Sequence, Under voltage,
        Over Voltage, Auto/Manual reset,
        Adjustable settings for Unbalance,
        UV/OV and trip delays,
        2 CO output relay

      TECHNICAL SPECIFICATION :-

      Supply Voltage    
        System : 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
        Auxillary : Built In (from 3 Phase)

      Output Contacts : 2 CO

      Trip Setting(Volts)    
        Phase Sequence : Yes 
        Phase Unbalance : 4 % - 20 % [Variable]

        Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      165-245V AC [Variable]
      95-135V AC [Variable]
      45-65V AC [Variable]
        Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      230-310V AC [Variable]
      130-170V AC [Variable]
      60-80V AC [Variable]

      Trip Time Delay
        On Phase Sequence : Instant
        On SP/UV/OV : 1 To 10 Sec [Variable)

      Resetting Mode : Auto/ External Manual Reset (External NC Push Buttons)

      Weight : 300 gms.

      Dimensions (mm)
        Overall (L x W x D) : 76 X 56.5 X 117.5
        Mounting (L x W) : 67 x 46    / 35 mm rail Mounting


      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

       

      APPLICATION:-

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane
        D2 VMR2D2 VMR2

       




      Advanced Protection Features

      Designed for industrial applications, the D2 VMR2 relay offers comprehensive phase protection: failure, reversal, and unbalance. The configurable phase unbalance threshold (nominally 30%) ensures sensitive and accurate fault detection, ideal for pumps and motors.


      Durable and User-Friendly Design

      Constructed with fire-retardant ABS material, the D2 VMR2 relay boasts a robust enclosure and compact form factor for easy integration onto DIN rails in control panels. The screw terminals ensure secure connections and straightforward installation.


      Reliable Performance Indicators

      Equipped with dedicated LED indicators for both supply and relay status, users can quickly verify operational conditions. The devices high mechanical life (>1 million operations) and strong insulation ensure long-term reliability in demanding environments.

      FAQs of Minilec Phase Failure Relays D2 VMR2:


      Q: How does the Minilec D2 VMR2 relay protect three-phase equipment?

      A: The D2 VMR2 relay monitors phase conditions to detect phase failure, phase reversal, and phase unbalance. When any issue is detected, it automatically activates its relay output to disconnect or alarm, thereby protecting motors and other equipment from electrical faults.

      Q: What is the recommended environment and mounting method for this relay?

      A: This relay is designed for ambient temperatures from -10C to +55C and should be mounted on a DIN rail in control panels or other industrial setups. Its compact size and screw-type terminals facilitate easy installation and secure wiring.

      Q: When is phase unbalance protection beneficial?

      A: Phase unbalance protection is critical when operating sensitive machinery such as pumps or industrial motors. It prevents overheating, vibration, and mechanical stress caused by uneven supply voltages, enhancing equipment lifespan and efficiency.

      Q: Where can the D2 VMR2 relay be used effectively?

      A: It is ideal for use in control panels, industrial machinery, motor setups, and pump houses where continuous three-phase power reliability is essential for safe and efficient operation.

      Q: What LED indications are provided by the D2 VMR2 relay?

      A: The relay features two LEDs: one indicates that supply power is ON; the other shows the relay operational status. These LEDs enable operators to quickly assess system health without additional equipment.

      Q: How does the automatic reset feature work in this relay?

      A: After detecting and acting on a phase fault, the relay automatically resets itself when the phase condition normalizes, ensuring minimal downtime and uninterrupted equipment protection without manual intervention.

      Q: What are the benefits of installing this phase failure relay in an industrial electrical system?

      A: Installing the D2 VMR2 relay reduces the risk of motor and equipment damage from phase-related faults, improves safety, minimizes production losses due to electrical issues, and provides rapid fault response and recovery.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2

      Contact Resistance : < 50 m

      Weight : Approx. 120 g

      Contact Form : 1C/O (SPDT)

      Usage : Protection and Monitoring of 3 Phase Supply

      Rated Voltage : 415V AC

      Protect Feature : Other, Phase Failure, Sequence & Unbalance Protection

      Minilec Phase Failure Relays VSP D1

      Minilec Phase Failure Relays VSP D1

      Contact Resistance : < 50m

      Weight : Approx. 150g

      Contact Form : 1 Changeover (SPDT)

      Usage : Protection of 3phase electrical equipment from phase failure

      Rated Voltage : 415V AC, 3 Phase

      Protect Feature : Other, Phase Failure, Phase Sequence and Phase Unbalance

      Minilec Phase Failure Relays ALV D2

      Minilec Phase Failure Relays ALV D2

      Contact Resistance : 100 m (initial)

      Weight : Approx. 100g

      Contact Form : 1 Changeover (SPDT)

      Usage : Industrial protection of threephase motors and equipment

      Rated Voltage : 415V AC

      Protect Feature : Other, Phase Failure, Sequence, and Unbalance Protection

      Minilec Phase Failure Relays S2 VMR6

      Minilec Phase Failure Relays S2 VMR6

      Contact Resistance : <100 m

      Weight : 110 g

      Contact Form : SPDT

      Usage : Phase Protection for Motors

      Rated Voltage : 415V AC

      Protect Feature : Other, Phase Failure, Phase Sequence, Phase Unbalance Protection