Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays D2 VMR1

      Minilec Phase Failure Relays D2 VMR1
      Minilec Phase Failure Relays D2 VMR1

      Minilec Phase Failure Relays D2 VMR1 Specification

      • Working Temperature
      • -10C to +55C
      • Contact Form
      • 1 Changeover (SPDT)
      • Protect Feature
      • Phase Loss, Phase Sequence, Voltage Asymmetry
      • Power Consumption
      • <2 VA
      • Coil Power
      • Internal, Not Applicable
      • Contact Material
      • Silver Alloy
      • Ambient Temperature
      • -10C to +55C
      • Contact Resistance
      • <100m
      • Dielectiric Strength
      • 2kV AC, 1 min
      • Mechanical Life
      • Over 10 Million Operations
      • Coil Voltage
      • Internal, Not Applicable
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >= 100M at 500V DC
      • Theory
      • Electromagnetic Relay
      • Usage
      • Phase Failure Protection
      • Contact Load
      • 5A @ 230VAC
      • Operate Time
      • <200 ms
      • Terminal Type
      • Screw Terminal
      • Rated Voltage
      • 415V AC, 3 Phase
      • Supply Terminal
      • L1, L2, L3
      • Size
      • Compact
      • Color
      • Grey
      • Dimension (L*W*H)
      • 90mm x 22.5mm x 70.5mm
      • Weight
      • Approx. 150g
      • Enclosure Material
      • ABS Flame Retardant
      • Response Time
      • Less than 200ms
      • Indication
      • LED for supply ON
      • Mounting Type
      • DIN Rail Mounting
      • Max. Switching Voltage
      • 250V AC
      • Minimum Load
      • 10mA at 5V DC
      • Output Relay
      • SPDT Heavy Duty Electromechanical
      • Phase Asymmetry Protection
      • >35V adjustable threshold
      • Degree of Protection
      • IP20
       
       

      About Minilec Phase Failure Relays D2 VMR1

      Minilec Phase Failure Relays

      OVERVIEW:-

        Suitable for 3 Ph-3W system,
        Microcontroller design,
        Absolute values of UV/OV settings,
        Phase Failure, Unbalance,
        Phase Sequence, under voltage,
        Over Voltage, Auto/Manual reset,
        Adjustable settings for Unbalance,
        UV/OV and trip delays,
        2 CO output relay

      TECHNICAL SPECIFICATION :-

      Supply Voltage    
        System : 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
        Auxillary : Built In (from 3 Phase)

      Output Contacts : 2 CO

      Trip Setting(Volts)    
        Phase Sequence : Yes 
        Phase Unbalance : 4 % - 20 % [Variable]

        Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      285-425V AC [Variable]
      165-225V AC [Variable]
      75-115V AC [Variable]
        Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      400-520V AC [Variable]
      230-290V AC [Variable]
      105-145V AC [Variable]

      Trip Time Delay
        On Phase Sequence : Instant
        On SP/UV/OV : 1 To 10 Sec [Variable)

      Resetting Mode : Auto/ Manual Reset (External NC Push Buttons)

      Weight : 300 gms.

      Dimensions (mm)
        Overall (L x W x D) : 76 x 56.5 x 117.5
        Mounting (L x W) : 67 x 46    / 35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      APPLICATION :-

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane

      D2 VMR1D2 VMR1



      Comprehensive Phase Protection

      The D2 VMR1 relay provides thorough protection against phase failure, phase reversal, and phase asymmetry, ensuring operational continuity for three-phase systems. Its adjustable asymmetry threshold enhances flexibility for various applications, making it suitable for both automation panels and motor protection needs.


      Reliable and Quick Response

      Thanks to a rapid response time of under 200 milliseconds, the relay reacts almost instantly to dangerous electrical conditions. It employs a heavy-duty electro-mechanical relay with 1 changeover contact (SPDT), ensuring robust performance and reliable switching for loads up to 5A at 230VAC.


      Durable Construction and Easy Installation

      Encased in a flame-retardant ABS enclosure, the D2 VMR1 has an IP20 protection rating, making it both safe and durable. Designed for DIN rail mounting, it offers straightforward installation, and screw terminals contribute to secure and easy wiringfor distributors, suppliers, traders, and installers across India.

      FAQs of Minilec Phase Failure Relays D2 VMR1:


      Q: How does the Minilec D2 VMR1 Phase Failure Relay protect my equipment?

      A: The relay monitors your three-phase supply for phase loss, incorrect phase sequence, and phase asymmetry. If it detects any irregularities, it reacts in less than 200ms by activating its internal relay to disconnect or signal the system, preventing potential equipment damage.

      Q: What are the installation requirements for the D2 VMR1 relay?

      A: Installation is simplemount the relay on a DIN rail and connect supply terminals L1, L2, and L3 using screw terminals. Ensure the system operates within the rated voltage of 415V AC and the ambient temperature range of -10C to +55C.

      Q: When should I use an adjustable phase asymmetry threshold?

      A: Adjust the phase asymmetry protection if your equipment needs tolerance customization for voltage fluctuations. Set the threshold above 35V for specific application requirements where transient imbalances could occur, ensuring precise response and optimal system safety.

      Q: Where can I use this relay?

      A: This relay is ideal for any environment where three-phase equipment requires protection: industrial plants, automation panels, pump stations, and commercial installations. Its compact design and IP20 rating suit indoor switchgear cabinets and protected locations.

      Q: What benefit does the LED indication provide?

      A: The LED indicator allows for quick and easy visual confirmation of supply status. When lit, supply is presentfacilitating routine checks and troubleshooting without specialized tools.

      Q: How durable is the relay for long-term use?

      A: With a mechanical life of over 10 million operations and robust silver alloy contacts, the D2 VMR1 ensures long-lasting, maintenance-free performance in demanding industrial and commercial settings.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Voltage Monitoring Relays Category

      Monitoring Relays S2 CMR3

      Monitoring Relays S2 CMR3

      Product Type : Monitoring Relay

      Contact Form : 1 CO (SPDT)

      Protect Feature : Other, Over/Under Voltage Protection

      Contact Load : Other, 250V AC, 5A (Resistive)

      Contact Resistance : 100 m

      Contact Material : AgCdO

      Monitoring Relays D1 VCT1

      Monitoring Relays D1 VCT1

      Product Type : Monitoring Relay

      Contact Form : SPDT

      Protect Feature : Other, Phase Loss, Phase Sequence, Under/Over Voltage

      Contact Load : Other, 5A at 250V AC

      Contact Resistance : 50 m max

      Contact Material : AgCdO

      Monitoring Relays OFS D1

      Monitoring Relays OFS D1

      Product Type : Monitoring Relay

      Contact Form : 1 Changeover (SPDT)

      Protect Feature : Other, Over/Under Voltage Protection

      Contact Load : Other, 5A 250V AC

      Contact Resistance : 100m

      Contact Material : Silver Alloy

      Monitoring Relays

      Monitoring Relays

      Product Type : Monitoring Relay

      Contact Form : 1 CO (SPDT)

      Protect Feature : Other, Over/Under Voltage, Phase Failure, Phase Sequence

      Contact Load : Other, 5A at 250V AC

      Contact Resistance : < 100 m

      Contact Material : Ag Alloy