Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2
      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2 Specification

      • Working Temperature
      • 0C to 50C
      • Contact Form
      • 1C/O (SPDT)
      • Coil Voltage
      • 415V AC (direct sensing from supply voltage)
      • Contact Material
      • Silver Alloy
      • Power Consumption
      • 2 VA max
      • Protect Feature
      • Phase Failure, Sequence & Unbalance Protection
      • Ambient Temperature
      • -10C to 55C
      • Contact Resistance
      • < 50 m
      • Dielectiric Strength
      • 2000V AC for 1 min
      • Coil Power
      • < 2 VA
      • Mechanical Life
      • Over 10 million operations
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >= 100M at 500V DC
      • Theory
      • Electromagnetic Relay
      • Usage
      • Protection and Monitoring of 3 Phase Supply
      • Contact Load
      • 5A @ 230V AC / 5A @ 28V DC Resistive
      • Operate Time
      • < 3 sec
      • Terminal Type
      • Screw Terminals
      • Rated Voltage
      • 415V AC
      • Supply Terminal
      • L1, L2, L3, N
      • Size
      • Compact
      • Color
      • Grey
      • Dimension (L*W*H)
      • 88 mm x 54 mm x 18 mm
      • Weight
      • Approx. 120 g
       
       

      About Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2

      Overview:-


      Phase Failure, Unbalance,

      Phase Sequence, Under voltage,

      Over Voltage, Manual Reset,

      Fixed Unbalance setting,

      Adjustable UV/OV settings,

      2 CO output relay

      Technical Specification:-

      Supply Voltage


      System : 110 / 240 / 380 / 415 / 440 V AC ±20% 50 / 60 Hz

      Auxillary : 110 V (Fixed) or (220 - 230 - 240) or
      (380 - 415 - 440) V AC ±20% selectable

      Output Contacts : 2 CO

      Trip Setting(Volts)


      Phase Sequence : Yes

      Phase Unbalance : 40 V ±6 V (fixed)


      Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 110 V AC
      line 80% to 95% (adjustable) of auxillary supply (±2% of set value)

      Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 110 V AC
      line 105% to 120% (adjustable) of auxillary supply (±2% of set value)

      Trip Time Delay

      On Phase Failure : 3.5 secs. ± 1.5 sec

      On UV/OV : Less than 2 secs. for OV & 2 - 5 secs for UV

      Resetting Mode : Manual / Remote

      Weight : 430 gms.

      Dimensions (mm)

      Overall (L x W x D) : 76 x 56.5 x 117.5

      Mounting (L x W) : 67 x 46 alt / 35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      * CE marked products available on request.

       Application:-

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane

       

      HLV D2HLV D2

      Robust Protection and Monitoring

      Minilec HLV D2 offers advanced protection against phase failures, incorrect sequences, and voltage imbalances. Its built-in short circuit protection and LED status indicators make monitoring seamless and reliable, ensuring operational continuity.


      Simple Installation and Operation

      Designed for DIN rail mounting with screw terminals, the relay is straightforward to install in control panels or distribution boards. Automatic reset and compact dimensions (88 mm x 54 mm x 18 mm) lend themselves to both new installations and quick replacements.


      Durable Design for Demanding Environments

      Featuring a flame-retardant ABS enclosure and capable of withstanding high humidity (up to 95% non-condensing) and temperatures from -10C to 55C, the HLV D2 is engineered for enduring performance in harsh industrial settings.

      FAQs of Minilec Phase Failure Relays HLV D2:


      Q: How does the Minilec Phase Failure Relay HLV D2 detect and respond to phase issues?

      A: The HLV D2 continuously monitors all three phases (L1, L2, L3) and the neutral. It detects phase failure, incorrect phase sequence, and voltage unbalance. When it identifies any abnormality, the relay trips within 3 seconds, activating the status LED for immediate fault identification and protection.

      Q: What is the process for installing the HLV D2 relay, and where is it typically used?

      A: Installation involves mounting the device on a DIN rail and connecting the three-phase supply to the L1, L2, L3, and N screw terminals. It is widely used in control panels and distribution boards to protect motors and critical three-phase equipment in industrial and commercial facilities.

      Q: When does the phase failure relay automatically reset, and how is the trip setting adjusted?

      A: The relay features an automatic reset function: once the detected fault is cleared (for example, correct phase sequence or voltage restored), it resets itself. Trip settings like unbalance sensitivity and trip delay can be fine-tuned via on-device controls for targeted protection.

      Q: What types of faults are indicated by the LEDs on the Minilec HLV D2, and how does this benefit users?

      A: LED indicators display both system status and the nature of any detected faults, such as phase loss, incorrect sequence, or voltage imbalance. This immediate visual feedback allows maintenance personnel to quickly identify and rectify issues, minimizing downtime.

      Q: How does the HLV D2 ensure user safety under short-circuit conditions?

      A: The relay incorporates built-in short-circuit protection, safeguarding itself and the connected loads. Its robust enclosure further prevents electrical hazards, contributing to the safe operation of industrial installations.

      Q: What makes the HLV D2 suitable for use in harsh environments?

      A: The device is built with flame-retardant ABS material, supports operation in ambient temperatures of -10C to 55C, and functions reliably in up to 95% non-condensing humidity. Its high insulation resistance and strong dielectric strength further enhance safety in demanding scenarios.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Phase Failure Relay HLV D2

      Phase Failure Relay HLV D2

      Weight : Approx. 110g

      Dimension (L*W*H) : 80mm x 22.5mm x 80mm

      Mechanical Life : 10^6 Operations

      Contact Load : Other, 8A at 250V AC

      Product Type : Phase Failure Relay

      Dielectiric Strength : 2kV AC for 1 minute

      Minilec Phase Failure Relays S2 VMR6

      Minilec Phase Failure Relays S2 VMR6

      Weight : 110 g

      Dimension (L*W*H) : 77 mm x 22.5 mm x 110 mm

      Mechanical Life : 10 Million Operations

      Contact Load : Other, 5A at 250V AC

      Product Type : Phase Failure Relay

      Dielectiric Strength : 2000V AC for 1 minute

      Minilec Phase Failure Relays VPG D1

      Minilec Phase Failure Relays VPG D1

      Weight : Approx. 120g

      Dimension (L*W*H) : 85mm x 35mm x 65mm

      Mechanical Life : Over 1,000,000 operations

      Contact Load : Other, 5A at 250V AC

      Product Type : Phase Failure Relay

      Dielectiric Strength : 2kV for 1 min. between output and supply terminals

      Minilec Phase Failure D1 VMR1

      Minilec Phase Failure D1 VMR1

      Weight : About 140g

      Dimension (L*W*H) : Approx. 70 mm x 22.5 mm x 73 mm

      Mechanical Life : >10 Million Operations

      Contact Load : Other, 5A at 250V AC (Resistive)

      Product Type : Phase Failure Relay

      Dielectiric Strength : 2kV, 50Hz for 1 min