Back to top
08045803208
Send SMS Send Inquiry


      Minilec Motor and Pump Protection Relays SPG D2

      Minilec Motor and Pump Protection Relays SPG D2
      Minilec Motor and Pump Protection Relays SPG D2

      Minilec Motor and Pump Protection Relays SPG D2 Specification

      • Working Temperature
      • -10C to +50C
      • Power Consumption
      • <4VA
      • Contact Form
      • 1 C/O (SPDT)
      • Contact Resistance
      • <50 m
      • Protect Feature
      • Phase Failure, Phase Sequence, Under/Over Voltage, Unbalance
      • Coil Voltage
      • Same as supply voltage
      • Dielectiric Strength
      • 2000V AC for 1 min
      • Ambient Temperature
      • -20C to +55C
      • Contact Material
      • Silver Alloy
      • Mechanical Life
      • 10^6 operations
      • Coil Power
      • <2W
      • Product Type
      • Motor and Pump Protection Relay
      • Insulation Resistance
      • >100 M at 500V DC
      • Theory
      • Electromechanical Relay
      • Usage
      • Motor and Pump Protection
      • Contact Load
      • 5A at 250V AC
      • Operate Time
      • 2-10 Sec Adjustable
      • Terminal Type
      • Screw Terminal
      • Rated Voltage
      • 415V AC
      • Supply Terminal
      • L1, L2, L3
      • Size
      • Compact
      • Color
      • White and Blue
      • Dimension (L*W*H)
      • 91 x 36 x 58 mm
      • Weight
      • 160 grams (approx.)
      • Storage Temperature
      • -25°C to +70°C
      • Reset Type
      • Automatic/Manual reset selectable
      • Enclosure Material
      • Flame Retardant ABS Plastic
      • Applicable Load
      • Three Phase Motors and Pumps
      • Indication
      • LED status indicators
      • Trip Setting
      • Adjustable settings for protection parameters
      • Humidity
      • Up to 95% RH (non-condensing)
      • Mounting Type
      • DIN Rail Mounting
      • Frequency
      • 50/60 Hz
      • Response Time for Phase Failure
      • <200 ms
       
       

      About Minilec Motor and Pump Protection Relays SPG D2

      Minilec Motor and Pump Protection Relays

       OVERVIEW :-


      Phase Failure

      Unbalance

      Phase sequence

      Overloading and Dry running Auto / Manual Reset

      Adjustable current trip settings

      Selectable overload characteristics

      1CO/2CO output relay

      TECHNICAL SPECIFICATION:- 

      Supply Voltage

      System : 100-120/220-240/380-440V AC ±20%

      Auxillary : 110/240/380/415/440 V AC/ 24 V AC/DC ±20%, 50 / 60 Hz

      Output Relay Contact : 1 CO (2 C0)

      Input : From CTS

      Trip Setting


      Phase to phase unbalance : 50% of motor Current

      Under current (Dry running) : 50%/75% of set current

      Overload : Above 120% of set current (IDMTL)

      UV/OV : N.A.

      Trip Time Delay

      On phase failure : 5.5 secs. ± 1.5 secs.

      For overloading : As per selectable inverse time Characteristics
      2 / 5 secs (10 secs.)

      UV/OV RP : N.A.

      Resetting : Auto / Manual / Remote

      Approx Weight : 425 gms.

      Dimensions (mm)

      Overall (L x W x D) : 76 x 56.5 x 117.5

      Mounting (L x W) : 67 x 46 alt / 35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      Selection Chart For CTS Times full Load Current
      S2 CTS1 S2 CTS1

       CONNECTION DIAGRAM:-

      Timing/ Relay logic Diagram

      Electrical Connection Diagram

      SPG D2 SPG D2

      APPLICATION :-

       Suitable for Panels in Following Apllications:


      Submersible Pump Control Panels.

      Air Handling Unit Fans.

      Belt Conveyor Motor panels for zero speed sensing.




      Optimized Motor & Pump Safety

      Guard your valuable equipment with reliable protection from phase-related issues and voltage anomalies. The SPG D2 helps extend the operational life and efficiency of three-phase motors and pumps by actively monitoring parameters and preventing damage from common electrical faults.


      User-Friendly Features

      The relay comes equipped with clear LED status indicators, easy-to-adjust protection parameters, and supports both automatic and manual resets for operational flexibility. Screw terminals ensure secure connections, while the compact design allows for quick DIN rail mounting in control panels.


      Built for Harsh Environments

      Engineered with flame-retardant ABS and designed to operate under high humidity and wide temperature ranges, the SPG D2 is suited for demanding industrial applications in diverse Indian climates. Its robust electrical specifications ensure long-term reliability and safety.

      FAQs of Minilec Motor and Pump Protection Relays SPG D2:


      Q: How does the SPG D2 relay protect motors and pumps?

      A: The SPG D2 monitors electrical parameters such as phase sequence, phase failure, under/overvoltage, and unbalance. When a fault is detected, it quickly disconnects the load within 200 ms, helping prevent damage to three-phase motors and pumps.

      Q: What are the benefits of using LED status indicators?

      A: LED status indicators provide instant visual feedback about relay and system conditions, enabling quick diagnostics and reducing downtime during maintenance or troubleshooting.

      Q: Where can the SPG D2 be installed?

      A: The relay is designed for DIN rail mounting, making it suitable for installation in electrical panels and enclosures commonly found in industrial, commercial, and agricultural settings across India.

      Q: When should I use the automatic versus manual reset option?

      A: Automatic reset is useful when you want the relay to restore power after the fault condition clears, ensuring quick resumption of operation. Manual reset provides better control and is ideal when safety protocols require an inspection before restarting equipment.

      Q: What is the process for setting protection parameters?

      A: Protection settings such as trip levels for voltage, unbalance, and operate time (210 seconds) can be easily adjusted using the onboard controls, allowing customization according to your motor or pumps requirements.

      Q: How does the relay support operation in extreme environments?

      A: The SPG D2 operates reliably in ambient temperatures from -20C to +55C, with storage tolerance up to +70C. It handles humidity up to 95% RH (non-condensing) and features a flame-retardant enclosure for enhanced safety.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Motor Protection Relay Category

      M Commander Protection Relay

      M Commander Protection Relay

      Operate Time : < 150 ms

      Insulation Resistance : >100M at 500V DC

      Contact Form : SPDT

      Contact Resistance : < 50m

      Protect Feature : Other, Overload, Phase Failure, Phase Sequence

      Size : Other, Standard DIN Rail Mount

      Minilec Motor and Pump Protection Relays S2 CTS1

      Minilec Motor and Pump Protection Relays S2 CTS1

      Operate Time : 1.5 Seconds Typical

      Insulation Resistance : >100 M at 500V DC

      Contact Form : SPDT

      Contact Resistance : <50 m

      Protect Feature : Other, Phase Failure, Phase Sequence, Under/Over Voltage, Single Phasing

      Size : Other, Compact

      Minilec Motor and Pump Protection Relays

      Minilec Motor and Pump Protection Relays

      Operate Time : Less than 2 seconds

      Insulation Resistance : >100M at 500V DC

      Contact Form : 1 C/O (Change Over)

      Contact Resistance : Less than 50 m

      Protect Feature : Other, Overload, Phase Failure, Phase Sequence, Under/Over Voltage

      Size : Other, Compact, DIN Rail Mountable

      Minilec Motor and Pump Protection Relays MPR D2

      Minilec Motor and Pump Protection Relays MPR D2

      Operate Time : 2.56 sec (Adjustable)

      Insulation Resistance : >= 100 M @ 500 V DC

      Contact Form : 1 Changeover (SPDT)

      Contact Resistance : < 100 m

      Protect Feature : Other, UnderVoltage, OverVoltage, Phase Failure, Phase Sequence, Dry Run

      Size : Other, Standard