Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays D1 HL S1

      Minilec Phase Failure Relays D1 HL S1
      Minilec Phase Failure Relays D1 HL S1

      Minilec Phase Failure Relays D1 HL S1 Specification

      • Coil Voltage
      • Internal to supply voltage
      • Working Temperature
      • -10C to +55C
      • Contact Form
      • 1 C/O (SPDT)
      • Coil Power
      • Low Power Consumption
      • Ambient Temperature
      • -10C to +55C
      • Contact Resistance
      • <50m
      • Protect Feature
      • Phase Failure, Phase Sequence, Phase Unbalance
      • Dielectiric Strength
      • 2kV AC for 1 Minute
      • Power Consumption
      • <2VA
      • Contact Material
      • Silver Alloy
      • Mechanical Life
      • >10 Million Operations
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >=100M at 500V DC
      • Theory
      • Electromagnetic Relay
      • Usage
      • Phase Protection for Motors and Equipment
      • Contact Load
      • 5A at 250V AC (Resistive)
      • Operate Time
      • About 200ms
      • Terminal Type
      • Screw Terminal
      • Rated Voltage
      • 415V AC, 3 Phase
      • Supply Terminal
      • L1, L2, L3
      • Size
      • Compact
      • Color
      • White & Blue
      • Dimension (L*W*H)
      • 77mm x 51mm x 110mm
      • Weight
      • Approx. 120g
      • Remote Battery Type
      • AAA
      • Operating System
      • Android
      • Smart TV Features
      • Built-in WiFi, Screen Mirroring
      • Sleep Timer
      • Yes
      • USB Ports
      • 2
      • Refresh Rate
      • 60 Hz
      • Viewing Angle
      • 178
       
       

      About Minilec Phase Failure Relays D1 HL S1

      Minilec Phase Failure Relays

      OVERVIEW :-

        Phase Failure, Unbalance,
        Phase Sequence,
        Under voltage, Over Voltage,
        Auto reset, Fixed Unbalance Setting
        Fixed UV/OV settings,
       

      2 CO output relay

      TECHNICAL SPECIFICATION :-

      Supply Voltage : 100-110-120/220-230-240/380-415-440V AC+20,-25%,
        System : 48-63 Hz, Selectable by Front Knob
        Auxillary : Built In

      Output Contacts : 2 CO

      Trip Setting(Volts)    
        Phase Sequence : Yes 
        Phase Unbalance : 10% (Fixed)

        Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 110 V AC
      line 75% of system supply (Fixed)
        Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 110 V AC
      line 120% of system supply (Fixed)

      Trip Time Delay
        On Phase Failure : 3.5±1.5 secs. [Fixed]
        On UV/OV : Less than 2 secs.

      Resetting Mode : Auto

      Weight : 200 gms.

      Dimensions (mm)
        Overall (L x W x D) : 76 x 30.5 x 117.5
        Mounting (L x W) : 68 centre to centre / 35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      * CE marked products available on request.

      APPLICATION :- 

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane

      D1 HLS1 D1 HLS1



      Advanced Motor Protection

      The Minilec D1 HL S1 Phase Failure Relay safeguards motors and equipment against critical power issues like phase failure, sequence anomalies, and phase unbalance. Its rapid response capability and accurate detection enhance operational safety and reliability, mitigating the risk of mechanical breakdowns.


      Effortless Installation & Maintenance

      Featuring a compact enclosure made from flame-retardant ABS plastic and DIN rail mountability, the relay is designed for streamlined installation in control panels. Screw terminal connections facilitate straightforward wiring, while LED indicators simplify status monitoring and fault diagnosis.


      Built for Indian Conditions

      This model operates efficiently across demanding thermal ranges and humidity levels typical in India. It tolerates ambient and working temperatures from -10C to +55C and stores safely between -20C and +70C. Its mechanical life exceeds 10 million operations, ensuring sustained performance in harsh environments.

      FAQs of Minilec Phase Failure Relays D1 HL S1:


      Q: How does the Minilec D1 HL S1 relay protect motors and equipment?

      A: The relay detects phase failure, incorrect phase sequence, and phase unbalance in three-phase systems. Upon sensing irregularities, it quickly interrupts the electrical circuit, protecting connected motors and equipment from potential damage or downtime.

      Q: What is the installation process for this phase failure relay?

      A: Installation is straightforward due to its DIN rail mountable design and screw terminal connectors. Simply secure the relay to the DIN rail in your control panel, connect supply terminals L1, L2, and L3, and wire the output terminals as per your system requirements.

      Q: Where can the D1 HL S1 model be used?

      A: It is suitable for industrial and commercial environments where three-phase motors or equipment require protection against abnormal power conditions. Common applications include pumps, compressors, HVAC systems, and machinery panels.

      Q: What are the benefits of the LED status indication?

      A: The integrated LED indication offers immediate visual feedback regarding the relays status and detected faults. This enables quick monitoring and diagnostics, significantly reducing maintenance times and ensuring prompt corrective action.

      Q: What is the operating voltage and contact rating of this relay?

      A: The relay is designed for 415V AC, 3-phase systems and features a contact load capacity of 5A at 250V AC (resistive). Its single change-over (SPDT) contact form uses durable silver alloy contacts for reliable switching.

      Q: Does this relay support operation in high humidity environments?

      A: Yes, the device is built to function in environments with relative humidity levels up to 95% non-condensing, making it suitable for use across diverse climatic conditions in India.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2

      Coil Power : < 2 VA

      Weight : Approx. 120 g

      Operate Time : < 3 sec

      Theory : Other , Electromagnetic Relay

      Rated Voltage : 415V AC

      Usage : Protection and Monitoring of 3 Phase Supply

      Minilec Phase Failure Relays S1 VMR7

      Minilec Phase Failure Relays S1 VMR7

      Coil Power : < 4 VA

      Weight : Approx. 120g

      Operate Time : 200ms (Approx.)

      Theory : Other , Electromagnetic Relay

      Rated Voltage : 415V AC (3 Phase)

      Usage : Protection of Motors and Equipment from Phase Failures, Phase Reversal and Under/Over Voltage conditions

      Minilec Phase Failure Relays S2 VMR1

      Minilec Phase Failure Relays S2 VMR1

      Coil Power : < 2VA

      Weight : 120g (approx.)

      Operate Time : Approximately 200ms

      Theory : Other , Electromagnetic Relay

      Rated Voltage : 415V AC (Three Phase) / 230V AC (Single Phase)

      Usage : Phase Failure and Sequence Monitoring in electrical systems

      Minilec Phase Failure Relays VSP D1

      Minilec Phase Failure Relays VSP D1

      Coil Power : < 3VA

      Weight : Approx. 150g

      Operate Time : 200ms maximum

      Theory : Other , Electromagnetic Relay

      Rated Voltage : 415V AC, 3 Phase

      Usage : Protection of 3phase electrical equipment from phase failure