Minilec Phase Failure Relays S1 VMR7
Minilec Phase Failure Relays S1 VMR7 Specification
- Power Consumption
- <4VA
- Contact Form
- 1 CO (SPDT)
- Coil Power
- < 4 VA
- Coil Voltage
- 415V AC
- Contact Material
- Silver Alloy
- Ambient Temperature
- -10C to +55C
- Dielectiric Strength
- 2 kV AC for 1 min
- Contact Resistance
- < 50 m
- Working Temperature
- -10C to +55C
- Protect Feature
- Phase Failure, Phase Sequence, Under/Over Voltage Protection
- Mechanical Life
- >1,000,000 operations
- Product Type
- Phase Failure Relay
- Insulation Resistance
- >= 100 M at 500V DC
- Theory
- Electromagnetic Relay
- Usage
- Protection of Motors and Equipment from Phase Failures, Phase Reversal and Under/Over Voltage conditions
- Contact Load
- 5A at 250V AC (Resistive)
- Operate Time
- 200ms (Approx.)
- Terminal Type
- Screw Type
- Rated Voltage
- 415V AC (3 Phase)
- Supply Terminal
- L1, L2, L3
- Size
- 22.5mm (Width modular)
- Color
- Grey/Black
- Dimension (L*W*H)
- 78mm x 22.5mm x 104mm
- Weight
- Approx. 120g
- Response Time
- <400 ms
- Trip Indication
- LED
- Enclosure Material
- Flame Retardant Plastic
- Standards Compliance
- IS/IEC 60947-5-1
- Mounting Type
- DIN Rail Mounting
- Relay Status Indicator
- LED Indication
- Adjustment
- Fixed/Pre-set (Non Adjustable)
- Frequency
- 50/60 Hz
About Minilec Phase Failure Relays S1 VMR7
Minilec Phase Failure Relays S1 VMR7
Overview:-
| Phase Sequence, | |
| Auto Reset, | |
| 1 CO Output Relay |
Technical Specification:-
| Supply Voltage | ||||||||||||||||||||||||
| ||||||||||||||||||||||||
| ||||||||||||||||||||||||
| Trip Time Delay | ||||||||||||||||||||||||
| ||||||||||||||||||||||||
| | ||||||||||||||||||||||||
| Dimensions (mm) | ||||||||||||||||||||||||
| ||||||||||||||||||||||||
| Note: | ||||||||||||||||||||||||
| ||||||||||||||||||||||||
Application:-
| Suitable for 3 Ph. equipments | |
| Agricultural Pump Starters. | |
| 3 Ph. Split AC machines. | |
| Hoist Motor Control | |
| Valve Actuator Motor | |
| Machine Tools | |
| Injection Molding M/c | |


Comprehensive Motor Protection
Specifically designed to detect and act against phase failure, phase reversal, and under/over voltage situations, the S1 VMR7 relay provides reliable protection for engines and electrical equipment. Its swift respond time reduces risk of equipment damage, ensuring system integrity and operational continuity in dynamic environments.
Quick Installation and Operation
The S1 VMR7s DIN rail mounting allows for convenient installation in standard panels. LED indicators clearly show relay and trip status, making it user-friendly and simplifying maintenance. The screw type terminal and modular design enable seamless integration into existing control systems.
Durable, Standards-Compliant Design
Housed in flame retardant plastic for superior safety, the relay is built for longevity, offering over one million mechanical operations. Compliant with IS/IEC 60947-5-1, it meets international benchmarks for reliability, making it suitable for distribution, supply, and trading networks in India.
FAQs of Minilec Phase Failure Relays S1 VMR7:
Q: How does the Minilec S1 VMR7 Phase Failure Relay protect my motor and equipment?
A: The S1 VMR7 continuously monitors all three phases for failures, incorrect phase sequence, and abnormal voltage conditions. If a fault is detected, it disconnects the load quickly (within 400 ms) to prevent damage from under/over voltage, phase loss, or reverse phase, ensuring your equipment remains protected.Q: What is the process for installing the S1 VMR7 relay?
A: The relay is designed for DIN rail mounting, which simplifies the installation process. Connect your power supply leads (L1, L2, L3) to the screw terminals as per the wiring instructions. Once installed, the LED indicators immediately inform you of the relay and trip status, making it easy to verify operation.Q: When should I use a phase failure relay like the S1 VMR7?
A: This relay is best used whenever there is a risk of phase failure, phase reversal, or voltage irregularities in three-phase systems such as those in industrial motors, pumps, or HVAC equipment. It helps prevent costly downtime and mechanical damage.Q: Where is the S1 VMR7 best suited for deployment?
A: It is ideal for use in electrical panels in commercial and industrial environments across India, especially where there is a high demand for reliable motor protection, including manufacturing plants, warehouses, and large building infrastructure.Q: What benefits do the LED relay and trip indicators offer?
A: The LED relay and trip indication provide instant visual feedback regarding relay status and trip events. This makes troubleshooting faster and helps maintenance teams quickly pinpoint any fault conditions without complex diagnostic tools.Q: Is the S1 VMR7 adjustable for different voltage thresholds?
A: No, the S1 VMR7 comes with fixed, pre-set thresholds and is non-adjustable. This simplifies operation, ensuring consistent protection according to its rated voltage specifications without the need for manual settings.Q: How does the relay ensure longevity and safety during operation?
A: Constructed from flame retardant plastic, meeting IS/IEC 60947-5-1 standards, and rated for over a million operations, the S1 VMR7 delivers durable performance and safe operation in a wide temperature range, ensuring long-term reliability in demanding settings.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Minilec Phase Failure Relays Category
Minilec Phase Failure D1 VMR1
Usage : Three Phase Motor Protection
Power Consumption : 2 VA Max.
Contact Form : 1 Changeover (SPDT)
Product Type : Phase Failure Relay
Dimension (L*W*H) : Approx. 70 mm x 22.5 mm x 73 mm
Terminal Type : Other, Screw Terminal
Minilec Phase Failure Relays VSP D1
Usage : Protection of 3phase electrical equipment from phase failure
Power Consumption : < 3VA
Contact Form : 1 Changeover (SPDT)
Product Type : Phase Failure Relay
Dimension (L*W*H) : 77mm x 22.5mm x 110mm
Terminal Type : Other, Screw terminal
Minilec Phase Failure Relays S2 VMR1
Usage : Phase Failure and Sequence Monitoring in electrical systems
Power Consumption : < 2VA
Contact Form : SPDT
Product Type : Phase Failure Relay
Dimension (L*W*H) : 80mm x 22.5mm x 94mm (approx.)
Terminal Type : Other, Screw type
Minilec Phase Failure Relays VST D1
Usage : Phase Failure/Sequence Protection
Power Consumption : Approx. 3 VA
Contact Form : 1 Change Over (1C/O)
Product Type : Phase Failure Relay
Dimension (L*W*H) : 22.5 x 77.5 x 110 mm
Terminal Type : Other, Screw Terminals
![]() |