Back to top
08045803208
Send SMS Send Inquiry


      Monitoring Relays

      Monitoring Relays
      Monitoring Relays

      Monitoring Relays Specification

      • Contact Resistance
      • < 100 m
      • Power Consumption
      • < 2 VA
      • Protect Feature
      • Over/Under Voltage, Phase Failure, Phase Sequence
      • Contact Form
      • 1 CO (SPDT)
      • Dielectiric Strength
      • 2 kV, 50/60 Hz for 1 min
      • Contact Material
      • Ag Alloy
      • Coil Power
      • < 2 VA
      • Coil Voltage
      • 230 V AC
      • Mechanical Life
      • > 10,000,000 operations
      • Product Type
      • Monitoring Relay
      • Insulation Resistance
      • > 100 M (at 500 V DC)
      • Theory
      • Electromagnetic Relay
      • Usage
      • Industrial Automation and Equipment Protection
      • Contact Load
      • 5A at 250V AC
      • Operate Time
      • < 200 ms
      • Rated Voltage
      • 230 V AC
      • Size
      • Standard DIN Rail
      • Color
      • Black & White
      • Dimension (L*W*H)
      • 22.5 x 78 x 100 mm
      • Weight
      • 120 g
      • Number of Phases
      • Single or Three Phase (Model Dependent)
      • LED Indication
      • Yes (Status/Trip)
      • Mounting Type
      • DIN Rail Mounting
      • Housing Material
      • Flame Retardant Plastic
       
       

      About Monitoring Relays

      Monitoring Relays OCS D1

      Overview

      • Single phase over current Auto reset,
      • Input 1A or 5 A through CT,
      • Adjustable over current trip settings,
      • Adjustable trip delay,
      • 1 CO output relay
      Applications
      • Suitable for following application:
      • Generator panels / AMF Panels.
        var dataref = new Object(); dataref = eval([{"lock":0,"mcat_id":"3307","old_new":0,"mcat_name":"Voltage Controllers"}]); ; var del_dataref = new Object(); del_dataref = eval([]); ;

      For More details :  Download the PDF file



      Advanced Protection for Industrial Equipment

      Safeguard your machinery with this monitoring relay featuring over/under voltage, phase failure, and phase sequence protection. Its fast response time ensures real-time defense against common power anomalies, making it ideal for industrial automation environments. The durable, flame-retardant housing provides extra safety in demanding settings.


      Effortless Installation and Operation

      Mounting the relay onto a standard DIN rail is straightforward and efficient. LED indicators deliver clear status and trip signals, simplifying monitoring and troubleshooting. Compact dimensions and light weight facilitate integration into both new and existing panels, boosting overall system reliability.


      Engineered for Longevity and Reliability

      Built to last, this relay offers a mechanical life surpassing 10 million operations, alongside superior insulation resistance and dielectric strength. The silver alloy contacts and stable coil design minimize maintenance needs, supporting continuous industrial operation with confidence.

      FAQs of Monitoring Relays:


      Q: How do I install the monitoring relay on a DIN rail?

      A: The relay is designed for standard DIN rail mounting. Simply align the relays mounting slot with the DIN rail and press until it clicks securely into place, ensuring firm attachment in your control panel.

      Q: What equipment can benefit from this monitoring relay?

      A: This relay is ideal for use in industrial automation systems and equipment requiring protection against voltage variations, phase failure, and incorrect phase sequencessuch as motors, pumps, compressors, and other critical devices.

      Q: What types of phase configurations does the relay support?

      A: Depending on the model, the relay can monitor either single-phase or three-phase power systems, providing flexible usage across various industrial setups.

      Q: Where can I see the operational status of the relay?

      A: The relay features integrated LED indicators that clearly display both status and trip conditions, enabling fast diagnostic checks directly on the device.

      Q: What are the benefits of the flame-retardant plastic housing?

      A: The flame-retardant housing enhances safety by reducing fire risks, providing additional protection for equipment and personnel in high-demand industrial environments.

      Q: How long is the relay expected to last under normal use?

      A: With a mechanical life exceeding 10 million operations, this relay is engineered for longevity and reliable operation in continuous industrial use.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Voltage Monitoring Relays Category

      Minilec Phase Failure Relays D2 VMR1

      Minilec Phase Failure Relays D2 VMR1

      Contact Resistance : <100m

      Usage : Phase Failure Protection

      Power Consumption : <2 VA

      Size : Other, Compact

      Protect Feature : Other, Phase Loss, Phase Sequence, Voltage Asymmetry

      Contact Load : Other, 5A @ 230VAC

      Monitoring Relays S2 CMR3

      Monitoring Relays S2 CMR3

      Contact Resistance : 100 m

      Usage : Industrial Automation, Motor Protection, Equipment Monitoring

      Power Consumption : <2VA

      Size : Other, 22.5mm (Width)

      Protect Feature : Other, Over/Under Voltage Protection

      Contact Load : Other, 250V AC, 5A (Resistive)

      Monitoring Relays D1 VCT1

      Monitoring Relays D1 VCT1

      Contact Resistance : 50 m max

      Usage : Phase Sequence and Phase Failure Monitoring

      Power Consumption : Less than 3 VA

      Size : Other, Compact

      Protect Feature : Other, Phase Loss, Phase Sequence, Under/Over Voltage

      Contact Load : Other, 5A at 250V AC

      Monitoring Relays OFS D1

      Monitoring Relays OFS D1

      Contact Resistance : 100m

      Usage : Industrial Automation, Control Panels

      Power Consumption : <2VA

      Size : Other, Standard

      Protect Feature : Other, Over/Under Voltage Protection

      Contact Load : Other, 5A 250V AC