Minilec Phase Failure Relays S2 VMR3
Minilec Phase Failure Relays S2 VMR3 Specification
- Working Temperature
- -10C to +55C
- Mechanical Life
- 1 million operations
- Contact Form
- SPDT (1 C/O)
- Contact Resistance
- < 50 m (initial)
- Contact Material
- Silver Alloy
- Protect Feature
- Phase failure, Phase sequence, Phase unbalance, Asymmetry, Under/Over voltage
- Power Consumption
- Less than 3 VA
- Ambient Temperature
- -10C to +55C
- Coil Voltage
- Operates on system voltage (415V AC)
- Coil Power
- Low power, integrated with relay
- Dielectiric Strength
- 2 kV AC for 1 minute between input and output
- Product Type
- Phase Failure Relay
- Insulation Resistance
- > 100 M at 500V DC
- Theory
- Electromechanical relay
- Usage
- Protection of motors and equipment from phase failure, sequence, and unbalance
- Contact Load
- 5A at 250V AC (Resistive Load)
- Operate Time
- 1-2 sec (typically)
- Terminal Type
- Screw type terminals
- Rated Voltage
- 415V AC (3 Phase, 4 Wire/3 Wire)
- Supply Terminal
- L1, L2, L3 (Phase to Neutral or Phase to Phase)
- Size
- Compact DIN rail mountable
- Color
- White and Blue
- Dimension (L*W*H)
- 78 mm x 22.5 mm x 70 mm
- Weight
- Approx. 180 grams
- Mounting Type
- DIN rail mountable / Surface mounting possible with adaptor
- Enclosure Material
- Flame retardant plastic enclosure
- Phase Sequence Protection
- Yes
- Storage Temperature
- -20°C to +70°C
- Response Time
- < 2 seconds
- Phase Asymmetry Setting
- Adjustable, typically 40% phase unbalance threshold
- Reset Type
- Automatic reset
- Relay Output Indication
- LED indication for relay status
- Compliance
- IEC 60255, IS 3231
About Minilec Phase Failure Relays S2 VMR3
Minilec Phase Failure Relays
OVERVIEW :-
| Microcontroller design, | |
| SMD Technology, | |
| Absolute values of UV/OV settings, | |
| Phase Failure, Unbalance, | |
| Phase Sequence, under voltage, | |
| Over Voltage, Auto/Manual reset, | |
| Adjustable settings for Unbalance, | |
| UV/OV and trip delays, | |
| 2 CO output relay |
TECHNICAL SPECIFICATION :-
| Supply Voltage | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Trip Time Delay | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| | ||||||||||||||||||||||||||
| Dimensions (mm) | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| | ||
| Note: | ||
|
APPLICATION :-
| Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load - | |
| AC & R Chiller compressor motors. | |
| AHU Fan /Pump Motors | |
| Machinery using multiple small motors. | |
| MAIN powers supply distribution panel board. | |
| DG Set application | |
| UPS | |
| Submersible Pumps | |
| Hoist & Crane | |


Comprehensive Motor Protection
The S2 VMR3 phase failure relay offers robust defense against a wide array of electrical faults, including phase loss, incorrect sequence, over or under voltage, and significant phase unbalance. With an adjustable phase asymmetry setting (typically at 40%), it enables fine-tuned protection suited to diverse operational requirements, supporting the longevity and safety of your critical equipment.
Versatile and Easy Installation
Installation is streamlined thanks to its DIN rail mountable design, with surface mounting achievable via an additional adaptor. The compact dimensions and screw-type terminals facilitate quick electrical connections, making it suitable for both retrofits and new installations. Its user-friendly design helps reduce setup time, ensuring swift deployment in various electrical panels.
Rigorous Safety and Durability Standards
Built with flame retardant plastic, the relay endures high temperatures and harsh industrial settings. It boasts insulation resistance greater than 100 M at 500V DC and dielectric strength of 2 kV AC, ensuring reliable operation and long service life. Compliance with international standards (IEC 60255, IS 3231) affirms its suitability for demanding applications across multiple sectors in India.
FAQs of Minilec Phase Failure Relays S2 VMR3:
Q: How does the S2 VMR3 Phase Failure Relay protect motors and equipment?
A: The S2 VMR3 monitors three-phase supply for faults such as phase failure, incorrect phase sequence, unbalanced voltage, and under or over voltage. Upon detection, the relay de-energizes its output within 12 seconds (typically <2 seconds), promptly isolating the equipment to prevent damage.Q: What are the mounting options for this relay, and where can it be installed?
A: The relay is DIN rail mountable for easy integration into standard control panels. If surface mounting is preferred, an adaptor allows for direct enclosure installation, making it suitable for industrial and commercial electrical panels.Q: When does the relay reset after a fault condition?
A: The relay features automatic reset. Once the detected electrical fault is cleared and the phase conditions return to normal, the relay resets itself without manual intervention, ensuring seamless operation.Q: What is the process for adjusting the phase asymmetry/unbalance setting?
A: The S2 VMR3 offers an adjustable phase asymmetry threshold, typically set at 40%. Users can fine-tune this setting according to site requirements, usually by accessing a dedicated adjustment dial or screw on the relay unit.Q: How does the LED relay output indication work?
A: An LED on the front panel offers visual confirmation of the relay status. It illuminates when the relay is energized (healthy condition), assisting with quick fault identification and operational status at a glance.Q: What are the main benefits of using this relay in your system?
A: Using the S2 VMR3 enhances equipment safety by preventing costly breakdowns due to electrical faults, increases system reliability with fast response time and automatic reset, and reduces maintenance intervention. Its compliance with key standards ensures trust and suitability for industrial use.Q: Where is the S2 VMR3 suitable for use in India?
A: This relay is ideal for motor control centers, distribution boards, pump houses, HVAC units, or any application requiring continuous protection of three-phase equipment across Indias diverse industrial environments.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Minilec Phase Failure Relays Category
Minilec Phase Failure Relays VSP D2
Working Temperature : 10C to +55C
Usage : Phase Failure Protection and Sequence Correction in Industrial Equipment
Color : Grey/White with Labelled Front Panel
Contact Load : Other, 5A at 250V AC (Resistive)
Terminal Type : Other, Screw type
Product Type : Phase Failure Relay
Minilec Phase Failure Relays S1 VMR7
Working Temperature : 10C to +55C
Usage : Protection of Motors and Equipment from Phase Failures, Phase Reversal and Under/Over Voltage conditions
Color : Grey/Black
Contact Load : Other, 5A at 250V AC (Resistive)
Terminal Type : Other, Screw Type
Product Type : Phase Failure Relay
Minilec Phase Failure Relays VSP D1
Working Temperature : 10C to +55C
Usage : Protection of 3phase electrical equipment from phase failure
Color : Grey
Contact Load : Other, 5A @ 250V AC
Terminal Type : Other, Screw terminal
Product Type : Phase Failure Relay
Minilec Phase Failure Relays S2 VMR2
Working Temperature : 10C to +55C
Usage : Industrial applications for phase protection
Color : White
Contact Load : Other, 5A at 230V AC / 28V DC
Terminal Type : Other, Screw Terminals
Product Type : Phase Failure Relay
![]() |
JAIN ELECTRICALS & ENGINEERS