Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays S2 VMR3

      Minilec Phase Failure Relays S2 VMR3
      Minilec Phase Failure Relays S2 VMR3

      Minilec Phase Failure Relays S2 VMR3 Specification

      • Working Temperature
      • -10C to +55C
      • Mechanical Life
      • 1 million operations
      • Contact Form
      • SPDT (1 C/O)
      • Contact Resistance
      • < 50 m (initial)
      • Contact Material
      • Silver Alloy
      • Protect Feature
      • Phase failure, Phase sequence, Phase unbalance, Asymmetry, Under/Over voltage
      • Power Consumption
      • Less than 3 VA
      • Ambient Temperature
      • -10C to +55C
      • Coil Voltage
      • Operates on system voltage (415V AC)
      • Coil Power
      • Low power, integrated with relay
      • Dielectiric Strength
      • 2 kV AC for 1 minute between input and output
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • > 100 M at 500V DC
      • Theory
      • Electromechanical relay
      • Usage
      • Protection of motors and equipment from phase failure, sequence, and unbalance
      • Contact Load
      • 5A at 250V AC (Resistive Load)
      • Operate Time
      • 1-2 sec (typically)
      • Terminal Type
      • Screw type terminals
      • Rated Voltage
      • 415V AC (3 Phase, 4 Wire/3 Wire)
      • Supply Terminal
      • L1, L2, L3 (Phase to Neutral or Phase to Phase)
      • Size
      • Compact DIN rail mountable
      • Color
      • White and Blue
      • Dimension (L*W*H)
      • 78 mm x 22.5 mm x 70 mm
      • Weight
      • Approx. 180 grams
      • Mounting Type
      • DIN rail mountable / Surface mounting possible with adaptor
      • Enclosure Material
      • Flame retardant plastic enclosure
      • Phase Sequence Protection
      • Yes
      • Storage Temperature
      • -20°C to +70°C
      • Response Time
      • < 2 seconds
      • Phase Asymmetry Setting
      • Adjustable, typically 40% phase unbalance threshold
      • Reset Type
      • Automatic reset
      • Relay Output Indication
      • LED indication for relay status
      • Compliance
      • IEC 60255, IS 3231
       
       

      About Minilec Phase Failure Relays S2 VMR3

      Minilec Phase Failure Relays

      OVERVIEW :-

        Microcontroller design,
        SMD Technology,
        Absolute values of UV/OV settings,
        Phase Failure, Unbalance,
        Phase Sequence, under voltage,
        Over Voltage, Auto/Manual reset,
        Adjustable settings for Unbalance,
        UV/OV and trip delays,
        2 CO output relay

      TECHNICAL SPECIFICATION :-

       

      Supply Voltage    
        System : 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
        Auxillary : Built In (from 3 Phase)

      Output Contacts : 2 CO

      Trip Setting(Volts)    
        Phase Sequence : Yes 
        Phase Unbalance : 4 % - 20 % [Variable]

        Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      285-425V AC [Variable]
      165-225V AC [Variable]
      75-115V AC [Variable]
        Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      :
      :
      :
      400-520V AC [Variable]
      230-290V AC [Variable]
      105-145V AC [Variable]

      Trip Time Delay
        On Phase Sequence : Instant
        On SP/UV/OV : 1 To 10 Sec [Variable)

      Resetting Mode : Auto/ Manual Reset [Selectable]

      Weight : 110 gms.(Approx)

      Dimensions (mm)
        Overall (L x W x D) : 90 X 35 X 60
        Mounting (L x W) : 35 mm Rail Mounting


      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      APPLICATION :-

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane
        S2VMR3S2VMR3

      Comprehensive Motor Protection

      The S2 VMR3 phase failure relay offers robust defense against a wide array of electrical faults, including phase loss, incorrect sequence, over or under voltage, and significant phase unbalance. With an adjustable phase asymmetry setting (typically at 40%), it enables fine-tuned protection suited to diverse operational requirements, supporting the longevity and safety of your critical equipment.


      Versatile and Easy Installation

      Installation is streamlined thanks to its DIN rail mountable design, with surface mounting achievable via an additional adaptor. The compact dimensions and screw-type terminals facilitate quick electrical connections, making it suitable for both retrofits and new installations. Its user-friendly design helps reduce setup time, ensuring swift deployment in various electrical panels.


      Rigorous Safety and Durability Standards

      Built with flame retardant plastic, the relay endures high temperatures and harsh industrial settings. It boasts insulation resistance greater than 100 M at 500V DC and dielectric strength of 2 kV AC, ensuring reliable operation and long service life. Compliance with international standards (IEC 60255, IS 3231) affirms its suitability for demanding applications across multiple sectors in India.

      FAQs of Minilec Phase Failure Relays S2 VMR3:


      Q: How does the S2 VMR3 Phase Failure Relay protect motors and equipment?

      A: The S2 VMR3 monitors three-phase supply for faults such as phase failure, incorrect phase sequence, unbalanced voltage, and under or over voltage. Upon detection, the relay de-energizes its output within 12 seconds (typically <2 seconds), promptly isolating the equipment to prevent damage.

      Q: What are the mounting options for this relay, and where can it be installed?

      A: The relay is DIN rail mountable for easy integration into standard control panels. If surface mounting is preferred, an adaptor allows for direct enclosure installation, making it suitable for industrial and commercial electrical panels.

      Q: When does the relay reset after a fault condition?

      A: The relay features automatic reset. Once the detected electrical fault is cleared and the phase conditions return to normal, the relay resets itself without manual intervention, ensuring seamless operation.

      Q: What is the process for adjusting the phase asymmetry/unbalance setting?

      A: The S2 VMR3 offers an adjustable phase asymmetry threshold, typically set at 40%. Users can fine-tune this setting according to site requirements, usually by accessing a dedicated adjustment dial or screw on the relay unit.

      Q: How does the LED relay output indication work?

      A: An LED on the front panel offers visual confirmation of the relay status. It illuminates when the relay is energized (healthy condition), assisting with quick fault identification and operational status at a glance.

      Q: What are the main benefits of using this relay in your system?

      A: Using the S2 VMR3 enhances equipment safety by preventing costly breakdowns due to electrical faults, increases system reliability with fast response time and automatic reset, and reduces maintenance intervention. Its compliance with key standards ensures trust and suitability for industrial use.

      Q: Where is the S2 VMR3 suitable for use in India?

      A: This relay is ideal for motor control centers, distribution boards, pump houses, HVAC units, or any application requiring continuous protection of three-phase equipment across Indias diverse industrial environments.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays VSP D2

      Minilec Phase Failure Relays VSP D2

      Working Temperature : 10C to +55C

      Usage : Phase Failure Protection and Sequence Correction in Industrial Equipment

      Color : Grey/White with Labelled Front Panel

      Contact Load : Other, 5A at 250V AC (Resistive)

      Terminal Type : Other, Screw type

      Product Type : Phase Failure Relay

      Minilec Phase Failure Relays S1 VMR7

      Minilec Phase Failure Relays S1 VMR7

      Working Temperature : 10C to +55C

      Usage : Protection of Motors and Equipment from Phase Failures, Phase Reversal and Under/Over Voltage conditions

      Color : Grey/Black

      Contact Load : Other, 5A at 250V AC (Resistive)

      Terminal Type : Other, Screw Type

      Product Type : Phase Failure Relay

      Minilec Phase Failure Relays VSP D1

      Minilec Phase Failure Relays VSP D1

      Working Temperature : 10C to +55C

      Usage : Protection of 3phase electrical equipment from phase failure

      Color : Grey

      Contact Load : Other, 5A @ 250V AC

      Terminal Type : Other, Screw terminal

      Product Type : Phase Failure Relay

      Minilec Phase Failure Relays S2 VMR2

      Minilec Phase Failure Relays S2 VMR2

      Working Temperature : 10C to +55C

      Usage : Industrial applications for phase protection

      Color : White

      Contact Load : Other, 5A at 230V AC / 28V DC

      Terminal Type : Other, Screw Terminals

      Product Type : Phase Failure Relay