      Minilec Microprocessor Pump Automation System

      Minilec Microprocessor Pump Automation System

      Product Details:

      X

      Minilec Microprocessor Pump Automation System Price And Quantity

      • 1 Unit

      Minilec Microprocessor Pump Automation System Trade Information

      • Telegraphic Transfer (T/T)
      • Depend on Order Per Month
      • As Per Requirement Week
      • All India

      Product Description

      Minilec Microprocessor Pump Automation System

      OVERVIEW :-


      Microcontroller based.
        Sensing voltage current and temperature
        Protecting against Phase Failure
        Unbalance
        Phase sequence
        Under/Over Voltage
        Overloading
        Winding over temperature
        Over current/Short circuit
        Auto/Manual resetting
        Locked rotor & earth fault
        On delay & start-up delay adjustable
        2x1CO output relays and serial communication port

      TECHNICAL SPECIFICATION:- 

       Supply Voltage

        System
        Auxillary
      :
      :
      415V AC +20%,-25% 3Ø, 3 Wire, 50 / (60)Hz ± 3%
      90-270V AC / DC

      Output : 1 CO for Trip & 1 CO for Alarm/RS 232 Port (Optional)

      Input : External CTS ( CT5/CT20/CT50 )

      Power Consumption : 8 VA

      Trip Setting  
      Setting Trip Level Trip Delay LED Reset
      Mode
      Power ON - - * -
      Unbal/Ph.Rev 1% - 20% 1-10 Secs. * Auto / Manual
      Under Voltage 75% - 95% 1-10 Sec * Auto / Manual
      Over Voltage 105% - 120% 1-10 Secs. * Auto / Manual
      Current unbalance 20-60% of Imax 1-10 Secs. * Multi
      Attempt
      Current phase Loss - 1-10 Secs. * Multi
      Attempt
      Under Current
      (dry run)
      } for
      CDR-M
      30-90% of Imax 1-10 Sec * Multi
      Attempt
      Over Current /
      Short Circuit
      300% - 800%
      of Imax
      2-25 Secs. * Multi
      Attempt
      Overload 2/5/10/15/20 Sec. As per IDMTL char. * Manual
      Lock Rotor 200%-500% of Imax 1-10 Secs. * Manual
      Earth Fault 30% - 80% 0.5 - 10 Secs. * Manual
      Winding Overheat 4K1 - 5K6 1-20 Secs. * Auto/
      Manual

      Display   16x2 (Back lit LCD Display)

      Dimensions (mm)
         
        Overall
      (L x W x D)
        Panel Mounting
      (L x W)
      :

      :
      166 x 216 x 80
       
      153 x 203
       

      Approx Weight : 600 gms

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      CONNECTION DIAGRAM:-

       

      Electical Connection Diagram

       
      MBMPR  

      Relay contact position shown in 'Power off' condition
       

      APPLICATION :-

      Suitable for Panels in Following Apllications:


      Heavy Duty Motors

      Crane Motors

      Screw Compressors

      AHU Fan Motors

      HT Motors

      Pump protection

      Pump House Automation.
       