Liquid Level Controller S2 WLC1
Liquid Level Controller S2 WLC1 Specification
- Frequency
- 50Hz
- Measuring Range
- Up to 10 meters
- Mounting Type
- Panel/Wall Mounted
- Installation Type
- Wall Mount
- Display
- LED Indicator Lights
- Switch Type
- SPDT Relay Switch
- IP Rating
- IP30
- Features
- Automatic Operation, Dry Run Protection, Long Service Life
- Current
- 6A max
- Sensor Type
- Float Sensor
- Protection Level
- Overload protection
- Phase
- Single Phase
- Pole Type
- Single Pole
- Usage & Applications
- Domestic and Industrial Water Tank Automation
- Connectivity Type
- Wired
- Output
- Relay Output
- Product Type
- Liquid Level Controller
- Working Temperature
- 0C to 50C
- Input
- 220V AC, 50Hz
- Pressure Type
- Atmospheric
- Diameter
- Standard (depends on sensor, approx. 3 cm)
- Application
- Water Level Sensing & Control
- Accuracy
- 1% of full scale
- Dimension (L*W*H)
- 110mm x 75mm x 50mm
- Weight
- Approx. 300g
Liquid Level Controller S2 WLC1 Trade Information
- Minimum Order Quantity
- 1 Unit
- Payment Terms
- Telegraphic Transfer (T/T)
- Supply Ability
- Unit
- Delivery Time
- As Per Requirement Months
- Main Domestic Market
- All India
About Liquid Level Controller S2 WLC1
Liquid Level Controller S2 WLC1 is a hi tech equipment which finds application in textile machinery, boilers, heat exchangers, soda machine, steam generators, water distribution pump house, etc. These electrical equipment, procured from reliable vendors after rigorous quality tests, are preferred for their precise dimension and smooth operation.
Features :
- Competitive pricing
- Easy to install
- Low maintenance
- Capable of withstanding voltage fluctuation
- Suitable for heavy duty applications
For More details : Download the PDF file
Reliable Water Level Monitoring
The S2 WLC1 ensures accurate and automatic control of water levels in various tank setups. Its float sensor delivers continuous monitoring up to 10 meters, offering peace of mind for both household and industrial users. The user-friendly LED indicators communicate operational status at a glance.
Advanced Protection and Longevity
With built-in overload and dry run protection, the controller minimizes the risk of equipment failure and extends its service life. The IP30-rated enclosure shields the internal electronics, supporting stable performance in controlled environments.
Seamless Installation and Versatile Application
Designed for easy wall or panel mounting, the S2 WLC1 fits effortlessly into new or existing water management systems. Its adaptability and precise relay output make it a preferred choice for distributors and suppliers catering to a wide range of automation needs.
FAQs of Liquid Level Controller S2 WLC1:
Q: How does the Liquid Level Controller S2 WLC1 function in water tanks?
A: The S2 WLC1 uses a float sensor to accurately detect water levels within a tank, providing real-time control. When the water reaches preset thresholds, the relay output automatically switches pumps or valves on or off, ensuring optimal water management.Q: What kind of environments is the S2 WLC1 suitable for?
A: This controller is built for both domestic and industrial applications such as water tanks and reservoirs where atmospheric pressure settings and temperatures between 0C and 50C are maintained.Q: When should I consider installing this liquid level controller?
A: It is advisable to install the S2 WLC1 whenever you need automated, reliable, and precise water level management, especially in setups prone to overflow or dry runs, to maximize equipment safety and reduce manual intervention.Q: Where should the controller be mounted for best results?
A: For optimal performance and safety, the S2 WLC1 should be wall-mounted or panel-mounted in a location protected from direct water ingress, in accordance with its IP30 rating.Q: What is the process for setting up and connecting the device?
A: Installation involves mounting the controller near your tank, connecting it to a 220V AC power supply, wiring the float sensor within the tank, and linking the relay output to control pumps or valves. Check connections and power before operation.Q: How does the S2 WLC1 benefit automation in water systems?
A: The device enables complete automation with features like automatic water level control, overload and dry run protection, reducing manual checks, and extending the lifespan of pumps. It improves efficiency and minimizes water wastage.
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 1077769 Units
- Delivery Time
- As Per Requirement Months
- Main Domestic Market
- All India
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Minilec Liquid Level Controllers Category
Liquid Level Controller P2 ALT1
Dimension (L*W*H) : 110 mm x 77 mm x 52 mm
Pole Type : Single Pole
Phase : Single Phase
Current : 5A max (relay output)
Supply Voltage : 230V AC
Accuracy : High accuracy, 3% (typ.)
Liquid Level Controller P1 LCW1
Dimension (L*W*H) : 85 mm x 55 mm x 60 mm
Pole Type : Single Pole
Phase : Single Phase
Current : 5A (Resistive Load)
Supply Voltage : 230V AC
Accuracy : 2% Full Scale
Liquid Level Controller DLC D1 And FRKP 1
Dimension (L*W*H) : 105mm x 55mm x 80mm
Pole Type : Single Pole
Phase : Single Phase
Current : 5A
Supply Voltage : 230V AC
Accuracy : High Level/Low Level Switching within 5mm
Liquid Level Controller FRKP 4
Dimension (L*W*H) : 72 x 90 x 52 mm
Pole Type : Single
Phase : Single Phase
Current : 6A (resistive load)
Supply Voltage : 230V AC 10%
Accuracy : High
![]() |