Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays S2 VMR2

      Minilec Phase Failure Relays S2 VMR2
      Minilec Phase Failure Relays S2 VMR2

      Minilec Phase Failure Relays S2 VMR2 Specification

      • Protect Feature
      • Phase failure, phase sequence, phase unbalance
      • Contact Resistance
      • < 100 m
      • Coil Power
      • Approx. 2VA
      • Contact Form
      • SPDT
      • Power Consumption
      • Approx. 2 VA
      • Contact Material
      • Silver Alloy
      • Mechanical Life
      • Over 10 million operations
      • Working Temperature
      • -10C to +55C
      • Dielectiric Strength
      • 2kV, 50Hz for 1 min
      • Coil Voltage
      • Same as rated supply voltage
      • Ambient Temperature
      • -10C to +55C
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >100 MOhm at 500V DC
      • Theory
      • Electromagnetic Relay
      • Usage
      • Industrial applications for phase protection
      • Contact Load
      • 5A at 230V AC / 28V DC
      • Operate Time
      • Less than 200ms
      • Terminal Type
      • Screw Terminals
      • Rated Voltage
      • 415V AC
      • Supply Terminal
      • L1, L2, L3
      • Size
      • 35mm DIN Rail Mount
      • Color
      • White
      • Dimension (L*W*H)
      • 78 x 22.5 x 90 mm
      • Weight
      • Approx. 120g
      • Frequency
      • 50/60Hz
      • Housing Material
      • Flame Retardant Plastic
      • Panel Cutout
      • DIN standard
      • Mounting Type
      • DIN Rail Mountable
      • Relay Output
      • 1 C/O (Change Over)
      • IP Rating
      • IP20
      • Response Time
      • <200ms
      • Status Indication
      • LED Indicators for phase status
      • Number of Phases
      • 3
       
       

      About Minilec Phase Failure Relays S2 VMR2

      Minilec Phase Failure Relays S2 VMR2

      Overview:-


      Microcontroller design,

      SMD Technology,

      Phase Failure, Unbalance,

      Phase Sequence, under voltage,

      Over Voltage, Auto reset,

      Fixed Unbalance setting,

      Fixed UV/OV settings,

      2 CO output relay

      Technical Specification:-

      Supply Voltage : 100-110-120 / 220-230-240 / 380-415-440V AC -25+20%,

      System : 48-63 Hz, Selectable by Front Knob

      Auxillary : Built In (from 3 Phase)

      Output Contacts : 2 CO

      Trip Setting(Volts)


      Phase Sequence : Yes

      Phase Unbalance : 10% (Fixed) ± 10%


      Under
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC
      lines ± 20% (Fixed)

      Over
      Voltage
      For 380-440V AC
      For 220-240V AC
      For 100-120V AC

      Trip Time Delay

      On Phase Failure : 2 - 5 Sec. (Fixed) / RP-Instant

      On UV/OV

      Resetting Mode : Auto Reset

      Weight : 100 gms.(Approx)

      Dimensions (mm)

      Overall (L x W x D) : 90 x 35 x 60

      Mounting (L x W) : 35 mm Rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      * CE marked products available on request.

      S2VMR2S2VMR2

      Application:-

      Suitable for monitoring 3 Ph. System supply from MAINS & used by motor load -

      AC & R Chiller compressor motors.

      AHU Fan /Pump Motors

      Machinery using multiple small motors.

      MAIN powers supply distribution panel board.

      DG Set application

      UPS

      Submersible Pumps

      Hoist & Crane

       

       



      Reliable Protection for Three-Phase Systems

      With advanced protection features against phase failure, reverse sequence, and unbalance, the Minilec S2 VMR2 relay ensures optimal operation and longevity for industrial equipment. Its fast response time and clear LED indicators make it effortless to detect and respond to supply anomalies, reducing downtime and enhancing safety on the shop floor.


      Effortless Installation and Integration

      Designed for DIN rail mounting, the S2 VMR2 fits seamlessly into standard panel configurations, making upgrades or replacements hassle-free. The screw terminals and standardized dimensions streamline the wiring process, while the robust build and flame-retardant plastic housing guarantee safe, long-term operation.

      FAQs of Minilec Phase Failure Relays S2 VMR2:


      Q: How does the Minilec S2 VMR2 phase failure relay protect industrial equipment?

      A: The relay continuously monitors all three phases for issues like phase failure, incorrect phase sequence, and phase unbalance. If any fault is detected, the relay triggers its output within 200ms, alerting the system and isolating equipment to prevent potential damage or downtime.

      Q: What is required for installing the S2 VMR2 relay in a control panel?

      A: The relay mounts directly onto a 35mm DIN rail, fitting within standard panel cutouts. It features screw terminals for secure connection to supply terminals L1, L2, and L3, and requires a rated supply voltage of 415V AC for operation. Its compact size (78 x 22.5 x 90 mm) makes it suitable for most industrial panels.

      Q: When will the LED indicators display phase faults on the relay?

      A: The built-in LED indicators provide real-time status for each phase. If theres a phase failure, wrong phase sequence, or phase unbalance, the corresponding LEDs instantly change status, allowing for immediate fault identification and timely intervention.

      Q: Where can the Minilec Phase Failure Relay S2 VMR2 be deployed?

      A: These relays are ideal for industrial applications across India, where three-phase protection is essential. Typical uses include motor protection, control panels, HVAC systems, and any equipment dependent on stable three-phase power.

      Q: What are the benefits of using a phase failure relay with a fast response time?

      A: A relay with less than 200ms response time, such as the Minilec S2 VMR2, minimizes risk of equipment malfunction or damage by reacting almost instantly to phase issues. This rapid intervention helps maintain process continuity and extend machinery lifespan.

      Q: How durable is the Minilec S2 VMR2 in industrial environments?

      A: The relay is built with flame-retardant plastic and an IP20 housing, offering long-term mechanical life of over 10 million operations, wide temperature tolerance, and strong resistance to dust and accidental contact, ensuring reliable performance in tough conditions.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays S2 VMR6

      Minilec Phase Failure Relays S2 VMR6

      Theory : Other , Electromechanical Relay

      Protect Feature : Other, Phase Failure, Phase Sequence, Phase Unbalance Protection

      Insulation Resistance : >100 M at 500V DC

      Contact Resistance : <100 m

      Terminal Type : Other, Screw Terminals

      Supply Terminal : L1, L2, L3

      Minilec Phase Failure D1 VMR1

      Minilec Phase Failure D1 VMR1

      Theory : Other , Electromagnetic Relay

      Protect Feature : Other, Phase Failure, Phase Reversal, Unbalance Faults

      Insulation Resistance : >=100M at 500V DC

      Contact Resistance : <100m

      Terminal Type : Other, Screw Terminal

      Supply Terminal : L1, L2, L3

      Minilec Phase Failure Relays VSP D1

      Minilec Phase Failure Relays VSP D1

      Theory : Other , Electromagnetic Relay

      Protect Feature : Other, Phase Failure, Phase Sequence and Phase Unbalance

      Insulation Resistance : >100M at 500V DC

      Contact Resistance : < 50m

      Terminal Type : Other, Screw terminal

      Supply Terminal : L1, L2, L3

      Minilec Phase Failure Relays VSP D2

      Minilec Phase Failure Relays VSP D2

      Theory : Other , Electromechanical Relay

      Protect Feature : Other, Phase failure, Phase sequence, and Phase unbalance protection

      Insulation Resistance : > 100 M at 500 V DC

      Contact Resistance : < 50 m (initial)

      Terminal Type : Other, Screw type

      Supply Terminal : L1L2 (3 Phase), LN (1 Phase)