      • Working Temperature
      • -10C to +55C
      • Protect Feature
      • Phase failure, Phase sequence, and Phase unbalance protection
      • Contact Resistance
      • < 50 m (initial)
      • Ambient Temperature
      • -10C to +55C
      • Dielectiric Strength
      • 2 kV, 50 Hz for 1 minute
      • Contact Form
      • 1 C/O (SPDT)
      • Mechanical Life
      • >10 operations
      • Coil Power
      • < 2 VA
      • Power Consumption
      • < 2 VA
      • Contact Material
      • AgCdO
      • Coil Voltage
      • Same as supply voltage
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • > 100 M at 500 V DC
      • Theory
      • Electromechanical Relay
      • Usage
      • Phase Failure Protection and Sequence Correction in Industrial Equipment
      • Contact Load
      • 5A at 250V AC (Resistive)
      • Operate Time
      • 200 ms (typical)
      • Terminal Type
      • Screw type
      • Rated Voltage
      • 415V AC (3 Phase) / 230V AC (1 Phase)
      • Supply Terminal
      • L1-L2 (3 Phase), L-N (1 Phase)
      • Size
      • 29 mm width
      • Color
      • Grey/White with Labelled Front Panel
      • Dimension (L*W*H)
      • 90 mm x 29 mm x 78 mm
      • Weight
      • Approx. 150 g
      • Output Contacts
      • 1 Changeover (SPDT)
      • Humidity
      • Up to 95% RH (non-condensing)
      • Storage Temperature
      • -20°C to +70°C
      • Mounting Type
      • DIN Rail Mounting
      • Application
      • Pumps, Motors, Compressors, Industrial Machines
      • Frequency
      • 50/60 Hz
      • LED Indication
      • Supply ON, Relay ON, Fault Condition
      • Maximum Allowable Voltage
      • 110% of rated voltage for short duration
      • Response Time
      • < 200 ms
       
       

      About Minilec Phase Failure Relays VSP D2

      Minilec Phase Failure Relays VSP D2

      Overview:-


      Phase Failure, Unbalance,

      Phase Sequence,

      Auto / Manual / Remote Reset

      Adjustable Unbalance Setting,

      2 CO output Relay

       

      Technical Specification:-

      Supply Voltage


      System : 100-120/220-240/380-440 V AC ± 20% 50/ 60 Hz

      Auxillary : 100-120/220-240/380-440 V AC ± 20%

      Output Contacts : 2 CO

      Trip Setting(Volts)


      Phase Sequence : Yes

      Phase Unbalance : 30 V to 70 V ± 6V (adjustable)

      Trip Time Delay

      On Phase Failure/ Unbalance : 3.5 sec. ± 1.5 sec.

      For Level Sensing : NA

      Resetting Mode : Auto / Manual / Remote

      Weight : 400 gms.

      Dimensions (mm)

      Overall (L x W x D) : 76 x 56.5 x 117.5

      Mounting (L x W) : 67 x 46 alt/35 mm rail Mounting

      Note:

      Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

      * Available on request.

      Overview:-


      Phase Failure, Unbalance,

      Phase Sequence,

      Auto / Manual / Remote Reset

      Adjustable Unbalance Setting,

      2 CO output Relay

      Application:-

       

      Suitable for following applications

      Inverter

      UPS

      Rectifier Panel

      Battery Charger Panel

      3 Phase AC Panel

      DG Set Panel

       

      VSP D2VSP D2

       



      Reliable Phase Protection

      The Minilec VSP D2 provides advanced phase monitoring to safeguard industrial machinery against electrical faults. Its built-in protections ensure the longevity of vital equipment by detecting phase failure, incorrect sequence, and unbalance, thereby preventing potentially costly downtime or damage.


      Simple Installation and Indication

      Featuring a compact DIN rail design and clearly labeled front panel, this relay offers straightforward mounting and wiring. Visible LED indicators immediately inform you of supply status, relay activation, or any fault conditions, making diagnostics and maintenance effortless in demanding environments.

      FAQs of Minilec Phase Failure Relays VSP D2:


      Q: How is the Minilec Phase Failure Relay VSP D2 installed in industrial equipment?

      A: The VSP D2 is designed for DIN rail mounting, allowing for quick and secure installation within electrical control panels. All terminals are screw type, enabling easy and reliable wiring for both single-phase and three-phase supplies.

      Q: What types of equipment can benefit from using this relay?

      A: This relay is suitable for various industrial machines such as pumps, motors, compressors, and general equipment requiring phase failure and sequence correction protection. Its versatile design accommodates both three-phase and single-phase systems.

      Q: When does the relay respond to phase faults, and how fast is its reaction time?

      A: The relay typically operates within 200 milliseconds when it detects phase failures, incorrect sequence, or phase unbalance, minimizing the chance of equipment malfunction or damage.

      Q: Where are the status indications displayed on the device?

      A: LED indicators on the relays labeled front panel clearly show the supply status, relay activation, or the presence of a fault condition, assisting quick troubleshooting and system monitoring.

      Q: What process does the relay use to protect against phase issues?

      A: The relay continuously monitors the incoming supply for three-phase or single-phase voltage irregularities. If any fault is detectedsuch as phase failure, wrong sequence, or unbalanceit quickly activates its output contact to disconnect or alert connected equipment.

      Q: How does using this relay benefit industrial operations?

      A: By providing rapid and reliable detection of phase-related problems, the VSP D2 helps prevent unscheduled downtime, reduces maintenance costs, and enhances the protection and lifespan of industrial assets.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Phase Failure Relay HLV D2

      Phase Failure Relay HLV D2

      Coil Power : <2VA

      Contact Material : Silver Alloy

      Coil Voltage : Same as Rated Voltage

      Rated Voltage : 415V AC (3 Phase) 50/60Hz

      Power Consumption : <2VA

      Usage : Industrial Equipment Protection, Motor Protection

      Minilec Phase Failure Relays VST D1

      Minilec Phase Failure Relays VST D1

      Coil Power : 3 VA

      Contact Material : Silver Alloy

      Coil Voltage : 415V AC (Builtin for Three Phase)

      Rated Voltage : 415V AC

      Power Consumption : Approx. 3 VA

      Usage : Phase Failure/Sequence Protection

      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2

      Coil Power : < 2 VA

      Contact Material : Silver Alloy

      Coil Voltage : 415V AC (direct sensing from supply voltage)

      Rated Voltage : 415V AC

      Power Consumption : 2 VA max

      Usage : Protection and Monitoring of 3 Phase Supply

      Minilec Phase Failure Relays D1 HL S1

      Minilec Phase Failure Relays D1 HL S1

      Coil Power : Low Power Consumption

      Contact Material : Silver Alloy

      Coil Voltage : Internal to supply voltage

      Rated Voltage : 415V AC, 3 Phase

      Power Consumption : <2VA

      Usage : Phase Protection for Motors and Equipment