Back to top
08045803208
Send SMS Send Inquiry


      Minilec Phase Failure Relays

      Phase Failure Relay HLV D2

      • Contact Material:Silver Alloy
      • Contact Resistance:<50m
      • Dielectiric Strength:2kV AC for 1 minute
      • Dimension (L*W*H):80mm x 22.5mm x 80mm
      • Rated Voltage:415V AC (3 Phase) 50/60Hz
      • Supply Terminal:L1, L2, L3, N
      • Weight:Approx. 110g
      • Supply Ability:Depend on Order Per Month

      Minilec Phase Failure Relays VSP D1

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A @ 250V AC
      • Insulation Resistance:>100M at 500V DC
      • Operate Time:200ms maximum
      • Power Consumption:< 3VA
      • Product Type:Phase Failure Relay
      • Size:Other, Compact

      Minilec Phase Failure Relays VSP D2

      • Coil Voltage:Same as supply voltage
      • Color:Grey/White with Labelled Front Panel
      • Contact Form:1 C/O (SPDT)
      • Contact Material:AgCdO
      • Dielectiric Strength:2 kV, 50 Hz for 1 minute
      • Dimension (L*W*H):90 mm x 29 mm x 78 mm
      • Usage:Phase Failure Protection and Sequence Correction in Industrial Equipment

      Minilec Phase Failure Relays S1 VMR7

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A at 250V AC (Resistive)
      • Contact Resistance:< 50 m
      • Operate Time:200ms (Approx.)
      • Power Consumption:<4VA
      • Supply Terminal:L1, L2, L3
      • Weight:Approx. 120g

      Minilec Phase Failure Relays S2 VMR1

      • Contact Load:Other, 5A at 250VAC Resistive
      • Contact Resistance: 50 m (initial)
      • Insulation Resistance:>= 100 M at 500 VDC
      • Operate Time:Approximately 200ms
      • Product Type:Phase Failure Relay
      • Supply Terminal:L1, L2, L3, N
      • Weight:120g (approx.)

      Minilec Phase Failure Relays S2 VMR2

      • Coil Voltage:Same as rated supply voltage
      • Color:White
      • Contact Form:SPDT
      • Dimension (L*W*H):78 x 22.5 x 90 mm
      • Rated Voltage:415V AC
      • Usage:Industrial applications for phase protection
      • Working Temperature:-10C to +55C

      Minilec Phase Failure Relays HLV D2

      • Contact Load:Other, 5A @ 230V AC / 5A @ 28V DC Resistive
      • Contact Resistance:< 50 m
      • Insulation Resistance:>= 100M at 500V DC
      • Operate Time:< 3 sec
      • Product Type:Phase Failure Relay
      • Supply Terminal:L1, L2, L3, N
      • Weight:Approx. 120 g

      Minilec Phase Failure Relays ALV D2

      • Coil Power:2VA
      • Contact Form:1 Changeover (SPDT)
      • Dielectiric Strength:2kV AC for 1 minute between terminal & enclosure
      • Mechanical Life:10 operations
      • Protect Feature:Other, Phase Failure, Sequence, and Unbalance Protection
      • Terminal Type:Other, Screw type
      • Theory:Other , Electromagnetic Relay

      Minilec Phase Failure Relays VMR D2

      • Color:Grey
      • Contact Form:1 C/O (SPDT)
      • Contact Material:Silver Alloy
      • Dielectiric Strength:2kV AC, 1 min
      • Dimension (L*W*H):77 x 22.5 x 110 mm
      • Rated Voltage:415V AC, 3 Phase
      • Working Temperature:-10C to +55C

      Minilec Phase Failure Relays D1 HL S1

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A at 250V AC (Resistive)
      • Contact Resistance:<50m
      • Operate Time:About 200ms
      • Power Consumption:<2VA
      • Supply Terminal:L1, L2, L3
      • Weight:Approx. 120g

      Minilec Phase Failure Relays VST D1

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A at 250V AC (Resistive)
      • Insulation Resistance:>100 M at 500V DC
      • Power Consumption:Approx. 3 VA
      • Product Type:Phase Failure Relay
      • Size:Other, Standard
      • Supply Terminal:L1, L2, L3 (Three Phase)

      Minilec Phase Failure D1 VMR1

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A at 250V AC (Resistive)
      • Contact Resistance:<100m
      • Operate Time:<200ms
      • Power Consumption:2 VA Max.
      • Supply Terminal:L1, L2, L3
      • Weight:About 140g

      Minilec Phase Failure Relays D2 VMR2

      • Coil Voltage:415V AC
      • Color:Grey/White
      • Contact Form:SPDT
      • Contact Material:Silver Alloy
      • Rated Voltage:415V AC (3 Phase)
      • Usage:Protection against phase failure and unbalance
      • Working Temperature:-10C to +55C

      Minilec Phase Failure Relays S2 VMR3

      • Ambient Temperature:-10C to +55C
      • Insulation Resistance:> 100 M at 500V DC
      • Operate Time:1-2 sec (typically)
      • Power Consumption:Less than 3 VA
      • Product Type:Phase Failure Relay
      • Size:Other, Compact DIN rail mountable
      • Supply Terminal:L1, L2, L3 (Phase to Neutral or Phase to Phase)

      Minilec Phase Failure Relays VPG D1

      • Ambient Temperature:-10C to +55C
      • Contact Load:Other, 5A at 250V AC
      • Contact Resistance:Below 50 m
      • Operate Time:Less than 200 ms
      • Size:Other, 35mm Module
      • Supply Terminal:L1, L2, L3
      • Weight:Approx. 120g

      Minilec Phase Failure Relays S2 VMR6

      • Coil Power:Internal
      • Mechanical Life:10 Million Operations
      • Protect Feature:Other, Phase Failure, Phase Sequence, Phase Unbalance Protection
      • Rated Voltage:415V AC
      • Terminal Type:Other, Screw Terminals
      • Theory:Other , Electromechanical Relay
      • Working Temperature:-10C to +55C