      Minilec Phase Failure Relays S2 VMR6 Specification

      • Dielectiric Strength
      • 2000V AC for 1 minute
      • Coil Power
      • Internal
      • Contact Form
      • SPDT
      • Ambient Temperature
      • -20C to +55C
      • Protect Feature
      • Phase Failure, Phase Sequence, Phase Unbalance Protection
      • Contact Material
      • AgCdO
      • Mechanical Life
      • 10 Million Operations
      • Power Consumption
      • 2VA
      • Contact Resistance
      • <100 m
      • Coil Voltage
      • Internal
      • Working Temperature
      • -10C to +55C
      • Product Type
      • Phase Failure Relay
      • Insulation Resistance
      • >100 M at 500V DC
      • Theory
      • Electromechanical Relay
      • Usage
      • Phase Protection for Motors
      • Contact Load
      • 5A at 250V AC
      • Operate Time
      • 200 ms
      • Terminal Type
      • Screw Terminals
      • Rated Voltage
      • 415V AC
      • Supply Terminal
      • L1, L2, L3
      • Size
      • Compact
      • Color
      • Grey
      • Dimension (L*W*H)
      • 77 mm x 22.5 mm x 110 mm
      • Weight
      • 110 g
      • Control Output
      • Relay Output
      • Frequency
      • 50/60 Hz
      • Hysteresis
      • 2% of Rated Voltage
      • Response Time
      • Instantaneous after Fault
      • Model Number
      • S2 VMR6
      • Relay Type
      • Voltage Monitoring Relay
      • Reset Type
      • Automatic
      • Degree of Protection
      • IP20
      • Mounting Type
      • 35 mm DIN Rail Mount
      • Suitable For
      • Three Phase Motor & Equipment
       
       

      About Minilec Phase Failure Relays S2 VMR6

      Minilec Phase Failure Relays

      OVERVIEW:-

        Microcontroller design,
        SMD Technology,
        Phase Failure, Unbalance,
        Phase Sequence, Under voltage,
        Over Voltage, Auto reset,
        Neutral Voltage,
        Adjustable UV/OV settings,
        2 CO output relay
        System supply voltage 415 VAC

      TECHNICAL SPECIFICATION :-

       

      Supply Voltage

      System : 415 VAC 20%, 3Phase, 4Wire System

      Auxillary : In Built

      Frequency : 48 to 63 Hz

      Output Relay Contacts : 2 CO

      Output Contacts Rating : 5 AMP1 240 VAC (Resistive)

      Unbalance Trip Setting : 94 V 6V ph - ph (Fixed)

      Trip Setting


      Under Voltage : 75% to 95% of 415 VAC

      Over Voltage : 105% to 125% of 415 VAC

      Power on Delay : 5 Sec. 1 Sec. (Fixed)

      Trip Time Delay

      *UB/ SP/UV/OV : 5 Sec. 1 Sec. (Fixed)

      *RP : Instant

      *Neutral Fail : Less than 2 Sec.

      Set Accuracy    

      *UB/ SP/UV/OV
      : 2 % of Set Value

      Resetting Mode : Auto Reset

      Reset Gap    

      *Unbalance reset gap

      *UV & OV reset gap
      : 14 V 4 V
      : 3% 1% of set value

      Enclosures : S2 Series, ABS / PC-ABS

      Weight : 110 gms. (Approx.)

      Dimensions (mm)

      Overall (L x W x D) : 90 x 35 x 60

      Mounting (L x W) : 35 mm rail Mounting

      S1 VMR7S1 VMR7

       




      Comprehensive Phase Protection

      The S2 VMR6 relay ensures reliable phase failure, phase sequence, and phase unbalance protection for critical three-phase motors and equipment. Its instantaneous response time and automatic reset mechanism minimize downtime and prevent equipment damage due to voltage anomalies, making it essential for industrial operations.


      Installation Made Simple

      This units compact design and standardized 35 mm DIN rail mounting make installation quick and straightforward in control panels. Screw terminals offer secure electrical connections, while the devices grey color and lightweight build streamline integration into various setups without occupying much space.


      Optimized Performance & Durability

      Built for longevity, the relay boasts a mechanical life of up to 10 million operations and withstands environments with temperatures from -10C to +55C. Its insulation resistance exceeds 100 M at 500V DC, and the IP20 rating ensures basic dust protection, making it well-suited for industrial environments.

      FAQs of Minilec Phase Failure Relays S2 VMR6:


      Q: How does the S2 VMR6 phase failure relay protect motors and equipment?

      A: The relay monitors three-phase voltage and instantly detects anomalies such as phase failure, incorrect phase sequence, or phase unbalance. Upon fault detection, it triggers a relay output, helping to prevent motor damage and operational breakdowns.

      Q: What is the process for mounting and wiring the S2 VMR6 relay?

      A: The relay is designed for easy installation on a 35 mm DIN rail. Wiring is accomplished via screw terminals labeled L1, L2, and L3 for supply connections, ensuring secure and straightforward panel integration.

      Q: When does the relay reset after a fault event?

      A: The S2 VMR6 features automatic reset, meaning it returns to normal operation as soon as the fault condition clears and all phases are within normal parametersno manual intervention is required.

      Q: Where can the S2 VMR6 relay be used?

      A: This relay is suitable for use in control panels protecting three-phase motors and equipment in industrial, commercial, and utility installations across India.

      Q: What are the usage benefits of the S2 VMR6 relay?

      A: It offers high-speed protection with an operation time 200 ms, maintains consistent performance even in fluctuating environments, and its compact size allows for flexible panel design without compromising on reliability.

      Q: What types of faults does the S2 VMR6 relay detect and respond to?

      A: It detects phase failure, phase sequence errors, and phase unbalance scenarios, providing an instantaneous relay output to safeguard connected equipment from potentially damaging electrical faults.

      Q: How durable is the S2 VMR6 relay for industrial applications?

      A: With a mechanical life rated at 10 million operations, IP20 protection, and robust insulation resistance, the relay is built to provide dependable service in demanding industrial settings.

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      More Products in Minilec Phase Failure Relays Category

      Minilec Phase Failure Relays ALV D2

      Minilec Phase Failure Relays ALV D2

      Size : Other, DIN Rail Mount

      Product Type : Phase Failure Relay

      Power Consumption : 2VA (approx.)

      Dimension (L*W*H) : 77 x 22.5 x 110 mm

      Mechanical Life : 10 operations

      Contact Resistance : 100 m (initial)

      Minilec Phase Failure Relays HLV D2

      Minilec Phase Failure Relays HLV D2

      Size : Other, Compact

      Product Type : Phase Failure Relay

      Power Consumption : 2 VA max

      Dimension (L*W*H) : 88 mm x 54 mm x 18 mm

      Mechanical Life : Over 10 million operations

      Contact Resistance : < 50 m

      Minilec Phase Failure Relays S1 VMR7

      Minilec Phase Failure Relays S1 VMR7

      Size : Other, 22.5mm (Width modular)

      Product Type : Phase Failure Relay

      Power Consumption : <4VA

      Dimension (L*W*H) : 78mm x 22.5mm x 104mm

      Mechanical Life : >1,000,000 operations

      Contact Resistance : < 50 m

      Minilec Phase Failure Relays S2 VMR1

      Minilec Phase Failure Relays S2 VMR1

      Size : Other, Compact, Standard DIN rail mountable

      Product Type : Phase Failure Relay

      Power Consumption : < 2VA

      Dimension (L*W*H) : 80mm x 22.5mm x 94mm (approx.)

      Mechanical Life : More than 10 million operations

      Contact Resistance : 50 m (initial)